MAINTENANCE
CREOSOTE
When wood is burned slowly, it produces tar and 
other organic vapours, which when combined 
with moisture, form creosote. The creosote va-
pours condense in the relatively cool chimney 
flue of a slow burning fire. As a result, creosote 
residue accumulates on the flue lining.  When 
ignited, this creosote can result in an extremely 
hot fire.
WARNING:  Things to remember in case 
of a chimney fire:
1. Close all draft and damper controls.
2. CALL THE FIRE DEPARTMENT.
Ways to Prevent and Keep Unit 
Free of Creosote
1)  Burn stove with the draft control wide open 
for  about  10-15  minutes  every  morning 
during burning season.
2)  Burn  stove  with  draft  control  wide  open 
for about 10 - 15 minutes every time you 
apply fresh wood. This allows the wood to 
achieve the charcoal stage faster and burns 
up any unburned gas vapours which might 
otherwise be deposited within the system.
3)  Only burn seasoned wood!  Avoid burning 
wet  or  green  wood.  Seasoned  wood  has 
been dried at least one year.
4)  A  small  hot  fire  is  preferable  to  a  large 
smouldering one that can deposit creosote 
within the system.
WOOD STORAGE
Store wood under cover, such as in a shed, or 
covered with a tarp, plastic, tar paper, sheets 
of scrap plywood, etc., as uncovered wood can 
absorb water from rain or snow, delaying the 
seasoning process.
MAINTENANCE
It is very important to carefully maintain your 
fireplace  stove,  including  burning  seasoned 
wood and maintaining a clean stove and chim-
ney system. Have the chimney cleaned before 
the burning season and as necessary during 
the season, as creosote deposits may build up 
rapidly. Moving parts of your stove require no 
lubrication.
 
5)  The chimney and chimney connector should 
be inspected at least once every two months 
during the heating season to determine is a 
creosote buildup has occured.
6)  Have chimney system and unit cleaned 
by competent chimney sweeps twice a 
year during the first year of use and at 
least once a year thereafter or when a 
significant layer of creosote has accu-
mulated (3 mm/1/8" or more) it should be 
removed to reduce the risk of a chimney 
fire. 
MAINTENANCE OF 
GOLD-PLATED DOORS
The gold electroplated finish on the door requires 
little maintenance, and need  only be cleaned 
with a damp cloth. DO NOT use abrasive ma-
terials or chemical cleaners, as they may harm 
the finish and void the warranty.
LATCH ADJUSTMENT
The door latch may require adjustment as the 
door gasket material compresses after a few 
fires.  Removal of the spacer washer, shown 
in the diagram below, will allow the latch to be 
moved closer to the door frame, causing a tighter 
seal.  Remove and replace the nuts, washer and 
spacer as shown.
 
DOOR GASKET
If the door gasket requires replacement 7/8" diam-
eter material must be used. Regency uses AMATEX 
# 10-863KR 7/8" dia. gasket (Part #846-570). A 
proper  high  temperature  gasket  adhesive  is 
required.  See your Regency Dealer.
 
GLASS MAINTENANCE
Your  Regency  stove  is  supplied  with  5  mm 
Neoceram ceramic glass (Part #846-302) that 
will withstand the highest heat that your unit will 
produce.  In the event that you break your glass 
by impact, purchase your replacement from an 
authorized Regency dealer only, and follow our 
step-by-step instructions for replacement (refer 
to Glass Installation section).
Allow the stove to cool down before cleaning 
the glass, do not clean the glass when it is hot. 
Do not use abrasive cleaners.