 U39 ULTIMATE Direct Vent Freestanding Gas Stove
For Vent Termination requirements, see 
 
"Exterior Vent termination Locations" section.
LOUVER 
INSTALLATION
1)  Attach the top & bottom louvers to the 
side stove panel using 2 screws per 
side.
INSTALLATION
MANUFACTURED 
MOBILE HOME 
ADDITIONAL 
REQUIREMENTS
1)  Ensure that structural members are not cut 
or weakened during installation.
2)  Ensure proper grounding using the #8 ground 
lug provided.
3)  Appliance must be anchored to the fl oor with 
the supplied anchoring methods. 
LOCATING  YOUR  
ULTIMATE GAS STOVE
 
When selecting a location for your stove, ensure 
that the clearances listed above are met as well 
as ensuring that there is adequate accessibility 
for servicing and proper operation.
A) Cross Corner 
B) Room Divider
C) Island  
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/ Alcove
VENTING  
INTRODUCTION
The DV Stove Horizontal Vent Kit and the 
Simpson Dura-Vent Direct Vent System Model 
DV-GS venting systems, in combination with the 
ULTIMATE Direct Vent Freestanding Gas Stove,  
U39-NG1, and U39-LP1, have been tested and 
listed as direct vent heater systems by Warnock 
Hersey. If converting a Class-A Metal Chimney 
or Masonry Chimney to a Direct Vent system, 
see instructions in "Converting a Class-A Metal 
Chimney or Masonry Chimey to a Direct Vent 
System" section.
These units use the "balanced  fl ue"  technology 
Co-Axial system. The inner liner vents products 
of combustion to the outside while the outer 
pipe draws outside combustion air into the 
combustion chamber thereby eliminating the 
need to use heated room air for combustion and 
losing warm room air up the chimney.
Note: These flue pipes must not be 
connected to any other appliance.
The gas appliance and vent system must be 
vented directly to the outside of the building, 
and never be attached to a chimney serving a 
separate solid fuel or gas burning appliance. 
Each direct vent gas appliance must use it's own 
separate vent system. Common vent systems 
are prohibited.
 IMPORTANT
Read all instructions carefully before starting the 
installation. Failure to follow these instructions 
may create a fi re or other safety hazard, and will 
void the warranty. Be sure to check the venting 
and clearance to combustible requirements. 
Consult your local building codes before 
beginning installation.
The location of the termination cap must conform 
to the requirements in the  "Exterior Vent Terminal 
Locations" section.
COMBUSTION AND 
VENTILATION AIR
The combustion air from this appliance is drawn 
from outside the building through the outer fl ue. 
Extra provision for combustion air inside the 
room is not required.
Minimum ceiling 
height is 36"/914mm 
from top of unit.