 Rear Flued Room Sealed Freestanding Gas Heater
Make it a practice to have all of your gas 
appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid 
fuels (wood, paper, cardboard, coal, etc.) 
be used in this appliance.
15) The appliance area must be kept clear and 
free of combustible materials, (gases and 
other fl ammable vapours and liquids).
INSTALLATION 
CHECKLIST
1)  Locate your gas stove. Refer to the following 
sections where applicable: 
 
a. Clearances to Combustibles
 
b. Exterior Flue Termination Locations
 
c. Planning Your Flue Installation
 d. 
Flueing
 
e. Flueing Installation Precaution
2)  Install fl ueing. Check all fl uing requirements. 
See "Flueing" to "Vertical Termination with 
Co-Linear Flex System" sections. 
3)  Make gas connections. Refer to the "Gas 
Connection" section. 
 
 
Test the pilot. Must be as per diagram in the 
"Maintenance Instruction" section.
4)  If necessary, convert from NG to LPG. 
Refer to "Conversion Kit from NG to LPG" 
section.
5)  Install standard and optional features. Refer 
to the following sections where applicable. 
 
 
a. Log Set Installation
 
b. Door Installation
 
c. Louvre Installation
 d. 
Optional 
Wall 
Thermostat
 
e. Optional Remote Control
6)  Test Gas Pressure. Refer to the "Gas Pipe 
Pressure Testing" section.
7)  Final check. Refer to the "Final Check" sec-
tion.
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained 
to customer.
This includes:
1)
  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
LOCATING YOUR 
REGENCY GAS STOVE
 
When selecting a location for your stove, ensure 
that the clearances listed above are met as well 
as ensuring that there is adequate accessibility 
for servicing and proper operation.
See the "Exterior Flue Termination Locations" 
section for Flue Termination requirements.
This appliance is Listed for bedroom  installations 
when used with a Listed Millivolt Thermostat. 
Some areas may have further requirements, 
check local codes before installation.
This appliance is Listed for Alcove installations, 
maintain minimum Alcove clearances as follows, 
minimum ceiling height of 1.7m,  minimum width 
of 1.0m and a maximum depth of  0.9m.
INSTALLATION
This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting or vinyl when 
the bottom pedestal cover plate (provided with 
unit) is installed.
Use the minimum clearances shown in the 
diagrams below:
F37-NG & F37-LPG Clearances
A  Side Wall to Unit 
190 mm
B  Back Wall to Unit 
76 mm
E Side Wall to Unit 
114 mm
F37-NG & F37-LPG
Reference Dimensions
C  Floor to Flue Centerline 
635 mm
D  Side Wall to Flue Centerline 521 mm
A) Cross 
Corner
B) Flush 
with 
Wall/Alcove
C)  Flat on Wall Corner
D) Flat 
on 
Wall
CLEARANCES TO 
COMBUSTIBLES
The clearances listed are MINIMUM distances. 
Measure the clearance to both the appliance and 
the chimney connector. The farthest distance is 
correct if the two clearances do not coincide.
 
For example, if the appliance is set as indicated 
in one of the diagrams but the connector is too 
close, move the stove until the correct clearance 
to the connector is obtained.  
This appliance may be installed only with the 
clearances as shown in the situations pictured. 
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances.
COMBUSTION AND 
VENTILATION AIR
The combustion air from this appliance is drawn 
from outside the building through the outer fl ue. 
Extra provision for combustion air inside the 
room is not required.
Minimum ceiling height is  
914mm from top of unit.