Regency FG37-LPG 用户手册

下载
页码 32
24
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
MAINTENANCE
FAN  MAINTENANCE
If  your  fan  requires  maintenance  or  replace-
ment  it  must  be  performed  by  an  authorised
person.  Access to the fan is through the plate
on the rear wall of the firebox.  NOTE: the unit
MUST  NOT  be  operated  without  the  fan
access  panel  securely  in  place  and  cor-
rectly  sealed.
IMPORTANT: These fans collect a
lot of dust from within your home.
Ensure you maintain these fan mo-
tors on a regular basis by vacuum-
ing out the fan squirrel cages, around
the motor, and around the grills on
the back of the stove.
TO REMOVE FAN
1) Unplug  or  disconnect  power  source  to
stove.
2) Remove the rear access panel on the back
of the stove. The fan can only be accessed
from the back of the stove.
IMPORTANT
Disconnect power supply
before servicing.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard  and  should  be  plugged
directly into a properly grounded
three-prong  receptacle.  Do  not
cut  or  remove  the  grounding
prong from this plug.
3) Unclip the wires from the fan motor.
4) Lift fan off of the 2 pins, tip back and pull
through the opening. Disconnect the green
ground wire from the right side of the fan
as soon as you can reach it.
REPLACING FAN
Reverse the above steps (1 - 4).  Make sure the
fan wires and the ground wire are reattached.
Hint for pushing fan down onto pins - rub a bit
of  dish  soap  on  the  grommet  so  it  will  slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.