Quadra-Fire CASTILE-GAS-CSB 用户手册

下载
页码 52
Page  22
July 29, 2008
Quadra-Fire · Castile Gas Stove · 7023-111E
High Wind 
Termination Cap
Top Adaptor
(3) Sheet Metal Screws
Flashing
Step 9.
Attach the flex to the retro connector. Use three sheet metal 
screws to attach the flex liner to the connector (Figure 
5.29
). Mount the retro connector to the masonry wall using 
masonry bolts. Redrill larger holes on connector as needed. 
Be careful to ensure that the connector is centered in the 
opening and the mounting holes line up with the masonry 
wall.
6 in. (152mm) diameter 
opening in masonry wall
(3) Masonry Bolts
(Not included)
Retro Connector
(4) Masonry Bolts 
(Not included)
Retro Connector
Wall Thimble Cover
 
Step 8.
Secure the top adapter to the flashing. Use three sheet 
metal screws through the side of the top adapter into the 
flange on the flashing (Figure 5.28). Twist lock the high 
wind termination cap on to the top adapter.
Figure 5.28  
Flex Liner
Flex Coupler
Sheet Metal Screws
Figure 5.27
Figure 5.29
Figure 5.30  
Step 10.
Slide wall thimble cover over retro connector and secure 
with masonry bolts (Figure 5.30). If you have a framed wall 
in front of the masonry, use wood screws to mount wall 
thimble cover to framed wall, over retro connector and 10 
in. (254mm) square framed opening (Figure 5.25, page 
21). If needed, add a section of direct vent pipe to the retro 
connector in order to extend through the opening in the wall 
thimble cover.
Step 11.
The connection between the appliance and the retro 
connector may be completed with sections of direct vent 
pipe.