2)  Turn gas control knob so indicator points 
to "OFF" position and allow 5 minutes for 
any gas in the combustion chamber to 
escape.
3)  Turn gas control knob counterclockwise 
so indicator points to the "PILOT" position. 
Depress the gas control knob fully. Depress 
the ignitor button several times until the 
pilot lights. After approximately one minute, 
release the gas control knob. The pilot fl ame 
should continue to burn. If the pilot does not 
remain lit, repeat operation allowing a longer 
period before releasing gas control knob.
4)  When the pilot stays lit, turn the gas knob 
further counterclockwise to the "ON" posi-
tion.
5)  Reinstall the glass door (refer to page 14).
6)  Use the switch, thermostat or remote control 
to turn on the unit.
7)  Rotate the fl ame height regulator to adjust 
the fl ame height higher or lower.
SHUTDOWN 
PROCEDURE
1)  Use the  switch, thermostat or remote control 
to turn off the main burner.
2)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
3)  Turn off all electric power to appliance if 
service is to be performed. 
FIRST FIRE
The fi rst fi re in your stove is part of the paint 
curing process. To ensure that the paint is 
properly cured, it is recommended that you 
burn your fi replace for at least four (4) hours 
the fi rst time you use it with the fan on. When 
fi rst operated, the unit will release an odour 
caused by the curing of the paint, the burning 
off of any oils remaining from manufacturing. 
Smoke detectors in the house may go off at 
this time. Open a few windows to ventilate the 
room for a couple of hours. 
The glass panel may require cleaning after the 
unit has cooled down.  
DO NOT ATTEMPT TO CLEAN THE 
GLASS WHILE IT IS HOT. 
Note:  When the glass is cold and the appli-
ance is lit, it may cause condensation 
and fog the glass. This condensation 
is normal and will disappear in a few 
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the ap-
pliance with the glass removed.
5)  Verify that the venting and cap are unob-
structed.
6)  Ensure that the brick panels, if used, are 
installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
LIGHTING 
PROCEDURE
IMPORTANT: Gas cock knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
1)  Turn burner OFF using "ON/OFF" switch.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length 
(Two-Wire) When Using Wall 
Thermostat (CP-2 System)
Wire Size                       Max. Length
Thermostat Wire Table
FINAL CHECK
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi ring 
correctly. This includes:
1)  Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15 
minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15 min. to stabilize.
3)  Check for proper draft.
CAUTION
Any alteration to the product that 
causes sooting or carboning that 
results in damage to the exterior 
facia is not the responsibility of 
the manufacturer.
During the fi rst  few  fi res, a white fi lm 
may develop on the glass front as part 
of the curing process. The glass should 
be cleaned or the fi lm will bake on and 
become very diffi cult to remove. Use a 
non-abrasive cleaner and NEVER clean 
the glass while it is hot.
IMPORTANT
Prior to igniting or reigniting the 
pilot, remove the glass door. 
Only when the pilot holds, without pressure 
being applied to the control knob, should you 
reinstall the glass door. The unit must not be 