2100 Millennium Wood Stove  (ACC)
B. Outside Air Kit Installation
1.  Remove all materials from packing box.
2.  Using a #2 Phillips screw driver attach the flex adapter to
the stove using 4 screws.
Figure 12.1. 
3.  For  floor  installations,  remove circular “knock-out” in the
base of the pedestal.
Figure 12.1.
4
.
 
Floor & Rear Installation: Cut a 4 inch (102mm) hole in
outside wall or floor to accommodate outside air piping.
Use 4 inch (102mm) aluminum metal flex or rigid piping
to directly connect outside air to appliance intake. Use
the supplied termination cap with a rodent screen. Seal
between the wall (or floor) and the pipe with silicone to
prevent moisture penetration.
Included in OAK-ACC: 
Termination  cap,  (2)  wire  ties,  flex
adapter, and fasteners
Included in SRV7033-041:
Cover plate and sealing rope (see
Floor Installation Alternative below,
Figure 12.2)
Items Needed for Installation (not supplied)
 •  4 inch flex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible, heat
resistant material up to 350
o
F. Cut the pipe to the required
length for your installation.
 • Phillips head screw driver
 • Silicone sealant
•  Drills and saws necessary for cutting holes through the
wall or flooring in your home
Figure 12.1 - Floor & Rear Installation
A source of air (oxygen) is necessary in order for combus-
tion to take place. Whatever combustion air is consumed
by the fire must be replaced. Air is replaced via air leakage
around windows and under doors. In homes that have tightly
sealed doors and windows, an outside air source is needed.
An optional Outside Air Kit is available.
Flex Line 
Wire Tie 
Wire Tie 
Flex Adapter 
Termination 
Cap 
For Floor Installa-
tions Remove 
Circular “Knock-Out” 
in Base of Pedestal.
WARNING
Do not draw outside combustion air from:
•  Wall, floor or ceiling cavity
•  Enclosed space such as an attic or garage
•  Close proximity to exhaust vents or chimneys
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage
from:
•  Leaves
•  Snow or ice
•  Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive
individuals.
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust flue.
•  Fire will not burn properly
 Smoke spillage occurs when door is opened due to
air starvation.
WARNING
Figure 12.2 - Floor Installation Alternative
Cover 
Plate 
5. 
Floor Installation Alternative:  In some instances you
may not be able to install the flex pipe as show in
Figure 
12.1. If that is the case, you will need to order SRV7033-
041  which  includes  a  cover  plate  and  sealing  rope  as
shown in
Figure 12.2. The goal is to seal the pedestal
so no room air can leak into the pedestal and to seal or
for cold air infiltration.