FPI U31-2 Gas Fireplace Insert
LOG SET 
INSTALLATION
Read the instructions below carefully and 
refer to the diagrams.  If logs are broken 
do not use the unit until they are replaced. 
Broken logs can  interfere with the pilot 
operation.
The gas log kit contains the following:
a) 02-43  Rear 
Log 
902-227
b)  02-45  Front Right Log 
902-229
c)  02-56  Middle Left Log 
902-230
d) 02-46  Left 
Top 
Log 
902-231
e) 02-47  Center 
Log 
902-232
f) 02-48 Middle 
Right 
Log  902-226
g)  02-44  Front Left Log 
902-228
h)    Embers 
 
902-154
i)    Rockwool  902-153
j)    Vermiculite  902-179/P 
Note:  Install Optional Brick Panels prior to 
installing logs.
Vermiculite and 
embers.
Vermiculite and 
embers.
Vermiculite and 
embers.
The "02" refer numbers (i.e. 02-43) are 
molded into the rear of each log.
Diagram 1
3)  After fi ve minutes, test that there is a “pull” on 
the fl ue by placing a smoke match, cigarette 
or similar device which gives off smoke, 
in front of the spill tube. To ensure a valid 
test, place a scrap piece of sheet metal (or 
other noncombustible material) between 
the spill tube and the upper louver, this will 
prevent the natural convection of the unit 
from interfering with the test. See diagram 
1.
Diagram 1
Diagram 2
Diagram 3
 
The smoke should be drawn into the spill tube. 
If the smoke is still not drawn into the spill tube, 
turn the unit off and check for the cause of the 
lack of draft. If  necessary, seek expert advice. 
For wind turbulent sites, a wind cap may remedy 
the problem.
Note: The thermally activated safety switch 
will sense the change in temperature and shut 
down the gas valve in the event of a severe 
downdraft or a blocked or disconnected 
vent. The switch acts as a safety shut-off to 
prevent a build-up of carbon monoxide.  If the 
fl ue is blocked or has no "draw", the switch 
will automatically shut off the supply of gas 
within 5 - 10 minutes. Tampering with the 
switch can result in carbon monoxide (CO) 
poisoning and possible death.
If the heater turns off because of lack of draft 
during the spillage test, check for the cause 
and if necessary, seek expert advice.
The thermally actuated safety switch will 
automatically reset after it has cooled off. 
The switch will continue to cycle until the 
draft problem is corrected. DO NOT BYPASS 
OR DISCONNECT THIS SWITCH.
OPTIONAL 
BRICK PANEL
1)  Unwrap the brick pattern panels from the 
protective wrapping.
2)  Remove the glass front if it is already in-
stalled.
3)  Put the rear brick panel fl at against the back 
of the unit.
4)  Before installing the side brick panels, loosen 
the screws for the brick tabs enough so that 
you can slide the brick tabs on to the screws 
easily but that the tabs are secure.  For the 
location of the side brick tab screws see 
diagram 1. 
5)  Remove the brick tabs and slide the side 
brick panels into position.  See diagram 3.  
Install the brick tabs.  See diagram 2.
INSTALLATION 
1)  Carefully remove the logs from the box and 
unwrap them.  The logs are fragile, handle 
with care - do not force into position.
2)  Sprinkle the vermiculite around the fi rebox 
base. Take  some of the embers (approx. 
 
1/3 of the bag) and sprinkle over the ver-
miculite.