Quadra-Fire 31M-ACC-MBK 用户手册

下载
页码 48
Page  12
7033-277C
March 2, 2007
R
3100 Wood Stove Series (ACC)
A.  Hearth Protection Requirements
FLOOR PROTECTION:  Floor protector must be non-com-
bustible material, extending beneath heater and to the front, 
sides and rear as indicated.  The fl oor must be non-com-
bustible or otherwise adequately protected from radiant heat 
given off by the unit and from sparks and falling embers.  A 
layer of thin brick or ceramic tile over a combustible fl oor is 
not suffi cient. 
For the Millennium Model In US installations,  it is nec-
essary to install a fl oor protector of a minimum of 3/8 inch 
(9.5mm) thick metal clad millboard or equivalent a minimum 
of 16 inches (406mm) in front of glass  and 8 inches (203mm) 
to both sides of the fuel loading door.  Open the door and 
measure 8 inches  (203mm) from the side edge of the open-
ing in the face of the appliance. *See exception. 
16" from glass
8 in.
USA
Fuel loading door
4-7/8 in.
3-1/8 in."
31-5/8 in.
minimum
39-5/8 in.
minimum
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
CANADA
203mm (8 in.)
203mm
(8 in.)
203mm
(8 in.)
457mm (18 in.)
1260mm
(49-5/8 in.)
minimum
1041mm (41 in.)
minimum
In Canada, similar fl oor protection must be provided 18 
inches (457mm) in front and 8 inches (203mm) from the 
sides and rear of the stove.  *See exception.
*EXCEPTION:  Non-combustible fl oor protections must 
extend beneath the fl ue pipe when installed with horizontal 
venting and extend 2 inches (51mm) beyond each side. 
See Figure 12.4.
USA required
Canada recommended
Figure 12.3
4
Installation
Figure 12.1
Figure 12.2
Figure 12.4
WARNING
Fire Risk.
•  Hearth pads must be installed exactly as 
specified.
High temperatures or hot embers may ignite 
concealed combustibles.
Millennium Model
op
tio
na
l co
ve
ra
ge
op
tio
na
l
co
ve
ra
ge
15
-7
/8
 in
.
49-7/8 in.
op
tio
na
l
co
ve
ra
ge
39
-5
/8
 in
.
16
 in
.
31
-5
/8
 in
.
27-5/8 in.
27-5/8 in.
11
-3
/8
 in
.
re
qu
ire
d
co
ve
ra
ge
49-7/8 in.
USA