Enviro EF3 用户手册

下载
页码 43
16
Installation
C
LEARANCES
 
TO
 C
OMBUSTIBLES
 - B
UILT
-I
N
 H
EATER
:
Refer to Figures 12 and 13.
Side wall to unit   
- 8 inches 
(20.3 cm)
Mantel projection  
- 10 inches  (25.4 cm)
Mantel to top of unit 
- 8 inches 
(20.3 cm)
Top facing to unit 
- 8 inches 
(20.3 cm)
Side facing to unit 
- 6 inches 
(15.2 cm)
Floor protection 
- 6 inches 
(15.2 cm)
(on either side and to the front  must be protected by 
non-combustible material)
Sides and rear walls to standoffs:   - 0 inches 
(0 cm)
Recess depth: 
- 11 inches   (30 cm) 
12"
(30.5 cm)
30"
(76 cm)
33"
(84 cm)
6"
(15 cm)
6"
(15 cm)
Floor Protection
Figure 13: EF3 Built-In Heater recommended 
framing. 
P
EDESTAL
 I
NSTALLATION
:
������� ���� ���
������ �����
Figure 14: Freestanding Pedestal. 
Figure 15: Fireplace Insert Pedestal. 
Figure 16: Built-In Heater Pedestal. 
• Place the unit on its back on the pallet.
• Back the four (4) 
5
/
16
” hex head screws in the base off 
three (3) to four (4) full turns.
• Align the keyholes in the pedestal with the screws, lock 
into place.
• Secure  the  two  (2)  pieces  by  tightening  the  four  (4) 
screws from the inside of the pedestal for the freestanding 
or from the outside of the pedestal for the FPI or BIH. 
The all models comes with a pedestal that has to be 
attached prior to installation:
• Remove the unit from the box
• Remove  the  freestanding  pedestal  from  the  box. 
Remove the FPI or BIH pedestal from the hopper