Enviro EF3 用户手册

下载
页码 43
REMOVAL:
When maintenance is required on the 
unit  the  surround  must  be  removed. 
Follow  steps  3  through  6  in  reverse 
order. 
The  side  panel  can  remain  attached 
because  they  swing  forward  for  easy 
access (refer to Figure 37).
Installation
���� ���������
����� ���
Figure 39: Side surround panel swings forward.
28
S
LIDER
/D
AMPER
 I
NSTALLATION
:
This is used to regulate the airflow through the pellet stove.
1.  Remove  the  slider  rod  (short  rod  with  knob  and  nuts)  from  their  package  and  open  the  left  side 
panel.
2. Remove the knob and outer nut from the knob.  Push the rod through the hole in the slider. Place the 
lock nut on the rod and tighten, leaving a 
1
/
32
” (1 mm) gap between the slider and the other nut.
3.  Make  sure  the  slider  moves  freely.  Close  the  side  panel  and  tighten  screws  after  placing  the  rod 
through the panel. Screw the knob onto the slider.
A Qualified Service Technician or Installer must set the Slider Damper. Taking a reading of 
vacuum  pressure  inside  the  firebox  with  a  magnehelic  gauge  can  be  used  to  set  the  slider  for  best 
combustion. The slider damper should be set only on a hot stove (operating for 30 minutes or more) by 
placing a Magnehelic Pressure Gauge in the firebox (test port is located in the center of the stove just 
below the door opening). The best settings are a reading of 0.12 to 0.13 inches of water column 
(30 Pa) on the high fire setting.  Some fuels may require higher or lower settings. The reading 
can be taken from the 1⁄8” (3 mm) hole located on the front of the unit below the door and behind the 
magnetic ash lip.
����� �����������
��� �� ���
����� ���� ���
��� �������
����������� ���
������
���� �����
���� �������
��� ����
��� �������
�����
Figure 40: Slider / damper assembly.