Installation
310863M
7
F
IG
. 3: Agitator Kit
Proportioner pump: follow instructions in propor-
tioner operation manual.
Air and fluid hoses: use only electrically conduc-
tive hoses. 
Air compressor: follow manufacturer’s recommen-
dations.
Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
Feed pumps and solvent pump: follow instruc-
tions in feed pump manual.
Object being sprayed: follow local code. 
Solvent pails used when flushing: follow local 
code. Use only conductive metal pails, placed on a 
grounded surface. Do not place the pail on a non-
conductive surface, such as paper or cardboard, 
which interrupts grounding continuity.
To maintain grounding continuity when flushing 
or relieving pressure: 
hold metal part of the spray 
gun/dispense valve firmly to the side of a grounded 
metal pail, then trigger the gun/valve.
The equipment was tested with lightweight oil, which is 
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a 
compatible solvent before using the equipment. See 
Flushing the System in the proportioner operation 
manual.
3.
Install agitator kit
a.
See F
IG
. 3. Install agitator (1) in drum.
b.
Screw air line fitting (2a) into agitator 
inlet. Connect air line coupler (2b) into 
fitting (2a).
4.
Connect air lines
a.
Shut off air valves at feed pumps.
b.
Connect air lines to quick disconnect fit-
tings at feed pump and agitator.
2b
1
2a
TI5514
5.
Grounding
WARNING
Your system must be grounded. Read warnings, page 
4.
6.
Flush Before Using 
Equipment