Lightolier 412U 用户手册
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
Job Information
Type:
Specification Decorative Performance Pendalyte
412U
Page 2 of 6
12" Compact Fluorescent
0°
250
500
750
1000
1250
1500
1750
2000
2250
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
500
1000
0°
15°
30°
45°
60°
75°
90°
105°
120°
135°
150°
165°
180°
750
250
450
900
0°
15°
30°
45°
60°
75°
90°
225
675
Satin aluminum Reflector Catalog No. 412U3 / 42SR, 32W CFL, 2400 Lumens.
white Glass Reflector Catalog No. 412U3 / 42WH, 32W CFL, 2400 Lumens.
amber Glass Reflector Catalog No. 412U3 / 42AB, 32W CFL, 2400 Lumens.
Report No. 2666FR
SC = .7
SC = .7
Report No. 2650FR
SC = .9
SC = .9
Report No. 2647FR
SC = .9
SC = .9
CaNDLEPOwER SUMMaRY
ANGLE MEAN CP LMS
0
2023
5
2015 188
10
1841
15
1554 440
20
1256
25
995 459
30
724
35
427 279
40
199
45
76
75
50
38
55
22
21
60
13
65
8
9
70
5
75
2
2
80
0
85
0
0
90
0
ZONaL LUMENS aND PERCENTaGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
1087
45.31
73.81
0-40
1366
56.93
92.74
0-60
1462
60.95
99.27
0-90
1473
61.39
100.00
40-90
107
4.46
7.26
60-90
10
.45
.73
90-180
0
.00
.00
0-180
1473
61.39
100.00
** EFFICIENCY = 61.4% **
ZONaL LUMENS aND PERCENTaGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
534
22.29
31.00
0-40
713
29.73
41.34
0-60
914
38.12
53.02
0-90
1169
48.74
67.78
40-90
456
19.01
26.44
60-90
254
10.62
14.76
90-180
556
23.17
32.22
0-180
1725
71.91
100.00
** EFFICIENCY=71.9% **
ZONaL LUMENS aND PERCENTaGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
555
23.13
53.49
0-40
740
30.85
71.34
0-60
921
38.38
88.76
0-90
1012
42.18
97.53
40-90
271
11.32
26.18
60-90
91
3.79
8.77
90-180
25
1.07
2.47
0-180
1037
43.25
100.00
** EFFICIENCY = 43.2% **
CaNDLEPOwER SUMMaRY
ANGLE MEAN CP LMS
ANGLE MEAN CP LMS
0
864
90
75
5
867
81
95
79
87
10
813
100
84
15
724 205
105
88 93
20
637
110
91
25
544 248
115
94 93
30
420
120
97
35
272 178
125
98 87
40
174
130
98
45
135 108
135
98 75
50
115
140
97
55
103 93
145
95 59
60
95
150
92
65
89 88
155
86 40
70
84
160
77
75
80 85
165
66 18
80
77
170
49
85
74 82
175
29
3
90
75
180
20
CaNDLEPOwER SUMMaRY
ANGLE MEAN CP LMS
ANGLE MEAN CP LMS
0
885
90
3
5
895
84
95
3
3
10
840
100
3
15
750 213
105
4
4
20
662
110
4
25
567 259
115
5
5
30
438
120
5
35
282
85
125
5
5
40
179
130
5
45
132 106
135
5
4
50
104
140
5
55
82
75
145
5
3
60
65
150
4
65
51
51
155
3
1
70
39
160
2
75
27
29
165
1
0
80
18
170
1
85
9
11
175
0
0
90
3
180
0
COEFFICIENTS OF UTILIZaTION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10
50 10
50 10 50 10 0
RCR
0
.73 .73 .73 .73 .71 .71 .68 .68 .65 .65 .61
1
.70 .69 .68 .66 .68 .65 .65 .63 .63 .62 .59
2
.68 .65 .63 .61 .64 .61 .62 .59 .60 .58 .56
3
.65 .62 .59 .57 .61 .57 .60 .56 .58 .55 .54
4
.63 .59 .56 .54 .58 .54 .57 .53 .56 .53 .51
5
.60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .48
6
.58 .53 .50 .48 .53 .48 .52 .48 .51 .47 .46
7
.55 .51 .48 .46 .50 .45 .49 .45 .49 .45 .44
8
.53 .48 .45 .43 .48 .43 .47 .43 .47 .43 .42
9
.51 .46 .43 .41 .46 .41 .45 .40 .45 .40 .39
10 .49 .44 .41 .39 .44 .39 .43 .39 .43 .38 .38
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Room Cavity Ratio
Zonal Cavity Method - Effective Floor Reflectance = 20%
COEFFICIENTS OF UTILIZaTION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10
50 10
50 10 50 10 0
RCR
0
.80 .80 .80 .80 .76 .76 .67 .67 .59 .59 .49
1
.73 .70 .67 .65 .66 .61 .59 .55 .52 .49 .41
2
.67 .62 .58 .54 .59 .52 .53 .47 .47 .43 .36
3
.63 .56 .51 .47 .53 .45 .48 .42 .43 .38 .32
4
.58 .51 .46 .42 .49 .40 .44 .38 .40 .35 .30
5
.55 .47 .41 .37 .45 .36 .41 .34 .37 .31 .27
6
.51 .43 .38 .34 .41 .33 .38 .31 .34 .29 .25
7
.48 .40 .34 .31 .38 .30 .35 .28 .32 ..26 23
8
.45 .37 .32 .28 .35 .27 .33 .26 .30 .24 .21
9
.42 .34 .29 .26 .33 .25 .30 .24 .28 .23 .20
10 .40 .32 .27 .24 .31 .23 .28 .22 .26 .21 .19
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 32.0
Room Cavity Ratio
Zonal Cavity Method - Effective Floor Reflectance = 20%
COEFFICIENTS OF UTILIZaTION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10
50 10
50 10 50 10 0
RCR
0
.51 .51 .51 .51 .50 .50 .47 .47 .45 .43 4.2
1
.48 .47 .46 .45 .46 .44 .44 .42 .42 .41 .39
2
.46 .43 .41 .40 .42 .39 .41 .38 .39 .37 .35
3
.43 .40 .38 .36 .39 .35 .38 .35 .37 .34 .32
4
.41 .37 .35 .33 .37 .32 .35 .32 .34 .31 .30
5
.38 .35 .32 .30 .34 .30 .33 .29 .32 .29 .28
6
.36 .32 .29 .28 .32 .27 .31 .27 .30 .27 .26
7
.34 .30 .27 .25 .30 .25 .29 .25 .28 .25 .24
8
.33 .28 .25 .24 .28 .23 .27 .23 .27 .23 .22
9
.31 .26 .24 .22 .26 .22 .26 .22 .25 .21 .21
10 .29 .25 .22 .20 .25 .20 .24 .20 .24 .20 .19
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 32.0
Room Cavity Ratio
Zonal Cavity Method - Effective Floor Reflectance = 20%
Notes: Amber Glass and Cobalt Blue Glass
have the same Photometrics.
30°
60°
30°
60°
30°
60°
225
450
675
900
250
500
750
500
1000
1500