1  FRAME-IN KIT INSTALLATION: See Frame-In Kit Instruction Sheet for installation procedure. 
2  POSITION TRIM CLIPS (Figure A):
  
Trim Clips (Quantity (4) on 1101 and 1001 series Frame-In Kits, Quantity (3) on 2001 series Frame-In Kits) must 
be positioned to extend inward towards center of aperture as shown in Figure A. Rotate into position if necessary. 
3 SNAP-ON 
(Figure 
B):  
Insert Socket Cup into neck of reflector.  Make sure springs of 
socket cup snap into reflector slots.  
 
NOTE: 
For optimum fixture performance, Lightolier recommends 
the Frame-In Kit, Lamp Type and Lamp Position combinations 
shown in the chart to the right.  (Vertical trims only.) 
Frame-In Kit 
Upper Trim Slot 
Lower Trim Slot 
18w Triple Tube 
2001 Series 
13w Quad Tube 
13w Triple Tube 
26w Triple Tube 
18w Triple Tube 
1001 Series 
13w Quad Tube 
13w Triple Tube 
42w Triple Tube 
32w Triple Tube 
26w Quad Tube 
26w Triple Tube 
1101 Series 
18w Quad Tube 
18w Triple Tube 
 
4  PUSH UP (Figure C):  
Push Reflector Trim straight up until it is tight against the ceiling.   
NOTE: To remove Reflector Trim, turn Reflector Trim counter-clockwise while pulling downward. 
 
Figure A
 
Figure B
 
 
 
Figure C 
 
Figure D 
For Wall Wash Series Trims: Position the trim so that wall wash reflector opening is pointed towards the wall to be 
illuminated before completing step 4 (Figure D).  This direction is indicated by a label on the Frame-In Kit. 
For Cross Blade Series Trims: Install Trim as instructed above in steps 1-4.  For re-lamping or to align the cross 
blade assembly to the ceiling, remove the cross blade cone assembly from the trim by pulling the cone portion of the 
assembly straight down (it may be necessary to repeat this at multiple positions to work the cross blade assembly out 
of the reflector).  To replace, align blades and push the cross blade cone assembly straight up into main trim reflector 
until each of the 3 cone retention clips are fully engaged in the groove on the exterior of the cone. 
For Lens Series Trims: Install Trim as instructed above in steps 1-4.  For re-lamping, remove just the lens support 
cone from the trim by inserting a finger between the lens and the support cone, gripping the cone and pulling straight 
down (it may be necessary to repeat this at multiple positions to work the cone out of the reflector).  The lens will hang 
from the reflector by a chain located behind the cone. To replace the lens and cone, place the lens on top of the 
support cone and push straight up into main trim reflector.  Make sure the lens chain is hidden behind the cone and 
does not interfere with the full engagement of the 3 cone retention clips into the groove on the exterior of the cone. 
 
READ AND UNDERSTAND THESE INSTRUCTIONS  
BEFORE INSTALLING LUMINAIRE. 
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at main power supply before proceeding. 
Retain these instructions for maintenance reference. 
INSTALLATION PROCEDURE FOR:
 
Lytecaster® 1101, 1001 and 2001 Series Trims
 
1101 Series Trims for use with 1101 Series Frame-In Kits only.  1001 Series Trims for use with 1001 Series Frame-In Kits only. 
2001 Series Trims for use with 2001 Series Frame-In Kits only. 
CAUTION: (RISK OF FIRE) 
FOR NON-IC RATED INSTALLATIONS, DO NOT INSTALL INSULATION ABOVE  
OR WITHIN 3 INCHES (76mm) OF ANY PART OF LUMINAIRE. 
 
CAUTION: 
USE ONLY WITH FRAME-IN KITS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURER’S FRAME-IN 
KITS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
 