1.  Advent Lytespan Track: 6063-T5 Aluminum 1.8mm wall thickness.
2.  Track Mounting Clips: 0.61mm Spring steel, in black or white; furnished with 
track units.
3.  Toggle Bolt & Screws: furnished with track units.
4.  Conductor (3): 16A current carrying capacity.
5.  Insulating Liner: 1.2mm wall, thermoplastic.
6.  Neutral Conductor: on bead side of track.
7.  Polarity Bead: identifies the neutral conductor.
8.  Live End: molded thermoplastic. Includes contacts for power supply leads.
9.  Dead End Cover: molded thermoplastic.
10. Mini Coupler: connects track units mechanically and electrically.
Mechanical
Track units plug together and lock securely to prevent accidental separation. Track 
units can be field cut.
Finish
All painted finishes are baked enamel.
Mounting
Track may be surface mounted to ceilings or walls. The track may be stem mount-
ed. The track is not intended to be cable mounted. The track can also be recessed, 
see Specification Sheet 7515.
Electrical
Two circuits individually controllable, rated 16 amps, at 220 - 240 volts 50 Hz 
per track circuit (16 amps total for the two circuits), when supplied by a 220/240 
volt, 50 Hz, single phase 3-wire branch circuit with a grounded neutral. The track 
is polarized and continuously grounded throughout. Electrical conductors are 
concealed in a insulating liner. Lytespan lighting units attach to the track at any 
point and can be adjusted to operate on either track circuit. Not intended for use 
with a power cord or a convenience receptacle adapter. Magnetic and electronic 
transformers require different dimmer controls. Use the proper control device on 
the track. Caution should be used when operating dimming controls on 3 wire 
circuiting (the neutral conductor may overload). For additional information on dim-
ming, call 1-800-833-3664. All wiring must be in accordance with National and 