Lightolier FBP60 产品宣传页
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
FBP Series Fluorescent Emergency Ballast
FBP60
Page 1 of 1
One or Two Lamp Operation 700 Lumens
Lightolier is a Philips group brand
Nickel Cadmium Battery
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
9.4”
(23.9 cm)
2.4”
(6.1 cm)
1.5”
(3.8 cm)
NOTES:
1. Maximum non-emergency lumen output can vary
1. Maximum non-emergency lumen output can vary
based on lamp manufacturer, ambient operating
temperature,and ballast manufacturer.
temperature,and ballast manufacturer.
2. Maximum emergency lumen output is based on total
output of one or two lamps, and can vary based on
lamp manufacturer and ambient operating tempera-
ture.
lamp manufacturer and ambient operating tempera-
ture.
3. Maximum emergency lumen output is supported for
a full 90 minutes of operation.
4. Consult factory for compatibility, operation and
performance of lamp types not listed.
Lamp Operation and Performance
NON-EMERGENCY
EMERGENCY OP.
LAMP
WATTAGE
BASE
MAX. LUMEN
MAX. LUMEN
EMERGENCY
TYPE
TYPE
OUTPUT
OUTPUT
LAMP OPERATION
F20T12
20
G13/Med Bi-Pin
1275
600 - 700
One or Two
F30T12
30
G13/Med Bi-Pin
2350
600 - 700
One or Two
F40T12
40
G13/Med Bi-Pin
2650
600 - 700
One or Two
F40T12/U
40
G13/Med Bi-Pin
3100
600 - 700
One or Two
F60T12
50
FA8/Single-Pin
3600
600 - 700
One
F72T12
55
FA8/Single-Pin
4500
600 - 700
One
F96T12
60
FA8/Single-Pin
5500
600 - 700
One
F24T12HO
35
R17D/Recessed
1620
600 - 700
One
F36T12HO
45
R17D/Recessed
2800
600 - 700
One
F48T12HO
60
R17D/Recessed
4050
600 - 700
One
F60T12HO
75
R17D/Recessed
5150
600 - 700
One
F72T12HO
85
R17D/Recessed
6350
600 - 700
One
F84T12HO
100
R17D/Recessed
7700
600 - 700
One
F96T12HO
95
R17D/Recessed
8000
600 - 700
One
F48T10
110
R17D/Recessed
6200
600 - 700
One
F17T8
17
G13/Med Bi-Pin
1350
600 - 700
One or Two
F25T8
25
G13/Med Bi-Pin
2150
600 - 700
One or Two
F32T8
32
G13/Med Bi-Pin
2950
600 - 700
One or Two
F32T8/U
32
G13/Med Bi-Pin
2700
600 - 700
One or Two
F40T8
40
G13/Med Bi-Pin
3725
600 - 700
One
F72T8
35
FA8/Single-Pin
3000
600 - 700
One
F96T8
50
FA8/Single-Pin
5950
600 - 700
One
FC6T9
20
G10Q/4--Pin
800
600 - 700
One
FC8T9
22
G10Q/4--Pin
1100
600 - 700
One
FC12T9
32
G10Q/4--Pin
1950
600 - 700
One
FC16T9
40
G10Q/4--Pin
2700
600 - 700
One
F39/36BX
39
2G11/4--Pin
2850
600 - 700
One
F40/30BX
40
2G11/4--Pin
3150
600 - 700
One
F50BX/FT55
50-55
2G11/4--Pin
4300 - 4800
600 - 700
One or Two
Features
1. Lamp Operation: Operates the following lamp types: T8 linear fluorescent,
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent.
See Lamp Operation and Performance table for specific lamp performance
and operation.
See Lamp Operation and Performance table for specific lamp performance
and operation.
2. Illumination: Provides 90 minutes of emergency illumination, and produces
600-700 lumens initial emergency light output. Can be used with most 17w
to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps without integral starters
including U-shaped, HO, VHO, circline, energy saving, and 4 pin compacts. It
is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, energy
saving and dimming AC ballasts.
to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps without integral starters
including U-shaped, HO, VHO, circline, energy saving, and 4 pin compacts. It
is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, energy
saving and dimming AC ballasts.
3. Housing: Constructed of 20 gauge steel with a white high temperature pow-
der coat paint finish. Slim housing allows for wireway channel mounting on
most recessed luminaires.
most recessed luminaires.
4. Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test
switch.
switch.
5. Battery: Maintenance free, sealed nickel cadmium battery has an estimated
service life of 10 years, and an operating temperature range of 32°F (0°C) to
131°F (55°C).
131°F (55°C).
6. Input Power Requirements: 3.5 watts max.
7. Warranty: Electronics: 3 years; Battery: 3 years.
7. Warranty: Electronics: 3 years; Battery: 3 years.
Code Compliance
UL 924 listed. UL damp location listing optional.
UL listed for use within sealed and/or gasketed luminaires.
UL listed for use within sealed and/or gasketed luminaires.
Complete Fixture consists of ballast unit. select options and accessories below.
Model #
Max. Lumens
Lamp Operation
FBP60
700
One or Two
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. Contact fac-
tory for other input voltages and frequencies.
DL = UL Damp Location Listing
tory for other input voltages and frequencies.
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote installa-
tion of test switch and pilot light.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote installa-
tion of test switch and pilot light.