Lightolier FBP1000-4P 产品宣传页

下载
页码 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0308
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
FBP Series Fluorescent Emergency Ballast
 
FBP1000-4P
Page 1 of 1 
One Lamp Operation 4-Pin Fluorescent Lamps 1,000  Lumens
Lightolier is a Philips group brand
Nickel Cadmium Battery
9.4”
(23.8 cm)
2.4”
(6.1 cm)
1.5”
(3.8 cm)
Features
1.  Lamp Operation: Operates the following lamp types: T4 Compact 
Fluorescent (4-pin base), 13W - 50W twin, quad and triple twin-tube without 
integral starter. See Lamp Operation and Performance table for specific lamp 
performance and operation.
2.  Illumination: Provides 90 minutes of emergency illumination, and produces a 
maximum of 1,000 lumens initial emergency light output. 
3.  Housing: Constructed of 20 gauge steel with a high temperature powder 
coat finish. Housing allows for frame mounting on most recessed luminaires. 
Housing includes 2’ lengths of flex conduit attached on each end.
4.  Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test 
switch.
5.  Battery: Maintenance free, sealed nickel cadmium battery has an estimated 
service life of 10 years, and an operating temperature range of 32°F (0°C) to 
131°F (55°C)
 
6.  Input Power Requirements: 3.5 watts max.
7.  Warranty: Electronics: 2 years; Battery: 2 years.
Code Compliance
U.L. 924 listed.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. Contact 
factory for other input voltages and frequencies. 
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RT = Remote Test Switch.
Complete Fixture consists of ballast unit. Select options and accessories below.
Model # 
Max. Lumens 
Lamp Operation 
 
FBP1000-4P 
1000 
One Lamp 4-Pin Fluorescent (without integral starter)
   
 
 
 Non-Emer.  Emer. Op. 
 
     
 
Non-Emer. 
Max. 
Max. 
Emer 
 Lamp 
 
Base 
 Lumen 
Lumen 
Lamp
 Type 
Watt.   Type 
Output 
Output 
Operation
 F18DBX/4P 
18 
G24Q-2 
1150 
500 
One or Two
 F26DBX/4P 
26 
G24Q-3 
1710 
675 
One or Two
 F18TBX/4P 
18 
GX24Q-2 
1200 
400 
One or Two
 F26TBX/4P 
26 
GX24Q-3 
1800 
600 
One or Two
 F32TBX/4P 
32 
GX24Q-3 
2200 
750 
One or Two
 F18BX 
18  2G11/4-Pin 
1250 
325 
One or Two
 F27/24BX/RS  27  2G11/4-Pin 
1800 
525 
One or Two
 F39/36BX/RS  39  2G11/4-Pin 
2850 
725 
One or Two
 F40/30BX/RS  40  2G11/4-Pin 
3150 
600 
One
 F50BX/RS 
50  2G11/4-Pin 
4000 
825 
One
 F162D/4P 
16 
GR10Q-4 
1050 
550 
One or Two
 F212D/4P 
21 
GR10Q-4 
1350 
550 
One or Two
 F282D/4P 
28 
GR10Q-4 
2050 
550 
One or Two
 F382D/4P 
38 
GR10Q-4 
2850 
675 
One or Two
F42TBXT4 
42  GX24Q-4P 
3200 
1000 
One
Notes:
 
1.  Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient operating 
temperature, and ballast manufacturer.
2.  Maximum emergency lumen output is based on total output of one or two lamps, and can vary 
based on lamp manufacturer and ambient operating temperature.
3.  Maximum emergency lumen output is supported for a full 90 minutes of operation.
4.  Consult factory for compatibility, operation and performance of lamp types not listed.
Lamp Operation and Performance