Lightolier AGR 产品宣传页

下载
页码 2
CANLYTE 
www.canlyte.com
525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221
WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH
© 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION) 
AGR
-AGW-1
Lighting Systems Agili-T Pendant Direct/Indirect 
AGR
/AGW
Page 1 of 2 
                             2 lamp T5 (lamp over lamp) 3 lamp T5 UP/DOWN per 4’ section
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
Coplanar Solo Parabolic/Flat Blade Louver
LIGHTOLIER 
A GENLYTE COMPANY 
www.lightolier.com
TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595          
631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131
Features
•  84.1% efficient (70% up/30% down) using T5 technology (2x F28T5).
•   Ultra-Light construction (4’ luminaire less than 15 lbs / 6.8 kg.) favors mobility, adds 
installation and remodeling convenience.
•  Wide indirect distribution for uniform ceiling luminance.
Construction
•  Parabolic louver optic made of matte aluminum / Flat Blade optic incorporates a  
 white 
finish
•  Unique contoured louver design with integral light stop
Labels
Electrical
•   Standard product offering (DI version, 120V and 277V only) includes continuous 2-circuit 
wiring, one circuit for the upper compartment (if applicable) and one circuit for the lower 
compartment (if applicable).  Single and double compartment luminaires can be mixed.
•   DA and DW available with Agili-T Network only.
•  18-gauge wire, maximum 10A per circuit.
Mounting
•  Suspension points on module:  every 4’ (4’ luminaire)
•   Fast installation using mounting clip for Standard T-bar and Slim T-bar or for Slot T-bar 
(see last page).
•  All canopy, suspension, power feed and mounting hardware included.
Finish
•  Seamless color and texture finish between luminaire and end-caps. 
•  
Available with textured (white or titanium) high resistant powder-based coating.
Options and accessories
• Emergency circuiting
**  If electrical junction box is needed to connect emergency wiring, order AGEB, AGES 
 or 
AGEO.
***  18-gauge wire. Maximum of 10A per breaker. 2 circuits using 2 breakers with common
 neutral.
INDIVIDUAL CONTROL 
• One circuit for AGR upper compartment controls 1 ballast and 2 T5/T5HO lamps
  for indirect lighting ( per 4’ of luminaire).
• One circuit for AGR lower compartment controls 1 ballast and 1 T5/T5HO lamp
  for direct lighting ( per 4’ of luminaire).
• Two ballasts allow control of direct/indirect light.
• Separate dimming available with Agili-T Network version.
54"
 36"
3"
48"
7 3/16"
2 1/16"
2 7/8"
51-1/2” (1308mm)
48” (1219mm)
7-3/16”
183mm
2-7/8”
74mm
2-1/16”
52mm
36”
914mm
3”
76mm
Ordering information
AG
Family
AG: Agili-T
R
Type
R:  Direct /Indirect
Independant
Mount Coplanar 
Solo with 
Parabolic Louver
W: Direct  /Indirect 
Independant 
Mount Coplanar 
Solo with Flat 
Blade Louver
4
Luminaire 
Length
4: 4’
P
Mounting
P: Pendant
GR
Housing Finish
GR:  Titanium
WH: White
DI
Wiring 
DI: Direct Power 
 Feed
6 wires,4 wires 
for 347V only
3
Lamp Qty 
in a cross 
section
2: 2 lamps
 (lamp 
over
 lamp)
3: 3 lamps 
 (2 
up, 
 1 
down)
28
Lamp
28: 28W T5
54: 54W 
 T5HO
UNV
Voltage
120: 120V
277: 277V
347: 347V
UNV: 
Universal 
Voltage 
120/277V
PG
          Ballast
DW: iGEN DALI 
Adressable T5/T5HO with 
Network-2 
MultiSense 
Integral Motion Sensor  
(120 or 277V only)
DA: iGEN DALI 
Adressable T5/T5HO 
(UNV only)
PG: Electronic Program 
Start T5/T5HO
Options