Lighting Systems
 
Baselyte-BSL1
Page  of 8   
2 Light T8 Direct/Indirect
Job Information 
Type:
 
Job Name: 
Cat. No.: 
 
Lamp(s): 
Notes: 
Lightolier 
a Genlyte Company 
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Ordering Information
Family
T = T8
6 = Direct/
Indirect
02
CN           
T
6
BSL
02 = 2 Light
CN = Cutout  
  w/baffles
04 = 4’
08 = 8’
12 = 2’
C = Custom Color
W = Standard
 
  White
Distribution
Lamp Type
No. of Lamps
Housing
Module Length
Wiring 
Voltage
Ballast
Finish
Weight = 3.0 lb./ft
Specifications
Features
.  Housing: die-formed 20ga. cold rolled steel
2.  End Set: die-cast metal with baked powder coat finish
3.  Lamping: two T8 lamps
4.  Configuration: 4’, 8’ and 2’ module lengths or continuous rows
5.  Ballasts: electronic 20V or 277V
Finish
High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements. 
Electrical
All luminaires are factory pre-wired to module ends with quick-wire 
connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Ordering Instructions
Individual Fixtures
.  Determine the number of individual modules required
2.  Order one end set per module
3.  Order one non-power mount per module
4.  Order one power mount per module
Continuous Rows*
.  Determine run length
2.  Order the appropriate number and length of modules for complete run 
3.  Order one end set for each run
4.  Order one non-power mount for each module
5.  Order one power mount per run
6.  Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the ‘Run 
Configuration’ table on next page for more details.
1 = 20V
2 = 277V 
= Standard  
<20% THD
= Standard  
<20% THD  
w/fusing
= <0% THD,  
Instant Start
= <0% THD,  
Instant Start  
w/fusing
= <0% THD,  
Program Start
= <0% THD,  
Program Start  
w/fusing    
1 = cct.
2 = 2cct. 
= cct. w/EC/NL
= 2cct. w/EC/NL
5 = cct. w/EM Battery
6 = 2cct. w/EM Battery
7 = cct. w/Dimming
= cct. w/cct.  
Thru wire
9 = 2cct. w/cct.  
Thru wire
Note: Please consult 
wiring section of spec
sheets for more
wiring options.