Lightolier C9E28VN 产品宣传页

下载
页码 2
**  EFFICIENCY = 42.7%  **
CERTIFIED TEST REPORT NO. 2460FR DATE:, FEB 19, 2004
SC = .7
COMPUTED BY LSI PROGRAM **TEST-LITE** 
Calculite
®
HID Downlight 
C9E28VN
Page 2 of 2
9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information
Type:
4,500
2,250
6,750
9,000
6,000
12,000
30°
60°
30°
60°
CEILING
80%
70%
50%
30%
WALL
70 50
30
10
50 10
50
10
50
10
RCR
0
.57 .57 .57 .57
.56 .56
.53 .53
.51 .51
.48
1
.55 .54 .53 .52
.53 .51
.51 .49
.49 .48
.46
2
.53 .51 .49 .48
.50 .47
.48 .46
.47 .45
.44
3
.51 .48 .46 .45
.47 .44
.46 .44
.45 .43
.42
4
.49 .46 .44 .42
.45 .42
.44 .41
.43 .41
.40
5
.47 .43 .41 .39
.43 .39
.42 .39
.41 .38
.37
6
.45 .41 .39 .37
.41 .37
.40 .37
.40 .36
.36
7
.43 .39 .37 .35
.39 .35
.38 .35
.38 .34
.34
8
.41 .37 .35 .33
.37 .33
.36 .33
.36 .32
.32
9
.39 .35 .33 .31
.35 .31
.34 .31
.34 .31
.30
10
.37 .33 .31 .29
.33 .29
.33 .29
.32 .29
.28
LUMINAIRE INPUT WATTS = 205
ANGLE
MEAN CP
LUMENS
0
9482
5
8632
809
10
7160
15
6075
1726
20
5041
25
3948
1829
30
2866
35
1919
1239
40
1185
45
666
530
50
218
55
23
60
60
3
65
1
1
70
0
75
0
0
80
0
85
0
0
90
0
175W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.      
ANGLE       MEAN CD/SQ M        
45
23031
55
988
65
78
75
32
85
0
**  EFFICIENCY = 48.0%  **
CERTIFIED TEST REPORT NO. 2450FR, DATE: FEB 12, 2004
SC = .6 
COMPUTED BY LSI PROGRAM **TEST-LITE** 
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS
% LAMP %LUMINAIRE
0-30
4363
33.82
70.45
0-40
5602
43.43
90.45
0-60
6191
48
99.97
0-90
6193
48.01
100.00
40-90
591
4.58
9.55
60-90
1
0.01
0.03
90-180
0
0
0
0-180
6193
48.01
100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
CEILING
80%
70%
50%
30%
WALL
70 50
30
10
50 10
50
10
50
10
RCR
0
.51 .51 .51 .51
.50 .50
.47 .47
.45 .45
.43
1
.49 .48 .47 .46
.47 .45
.45 .44
.44 .43
.41
2
.47 .45 .44 .43
.44 .42
.43 .41
.42 .40
.39
3
.45 .43 .41 .40
.42 .39
.41 .39
.40 .38
.37
4
.43 .41 .39 .37
.40 .37
.39 .37
.38 .36
.35
5
.41 .39 .36 .35
.38 .35
.37 .34
.37 .34
.33
6
.40 .37 .34 .33
.36 .33
.36 .33
.35 .32
.32
7
.38 .35 .32 .31
.34 .31
.34 .31
.33 .30
.30
8
.36 .33 .31 .29
.32 .29
.32 .29
.32 .29
.28
9
.35 .31 .29 .27
.31 .27
.30 .27
.30 .27
.27
10
.33 .30 .27 .26
.29 .26
.29 .26
.29 .26
.25
LUMINAIRE INPUT WATTS = 290
ANGLE
MEAN CP
LUMENS
0
11750
5
11130
1042
10
9674
15
8222
2335
20
6835
25
5292
2464
30
3878
35
2612
1680
40
1598
45
900
716
50
299
55
23
77
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
250W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.      
ANGLE       MEAN CD/SQ M        
45
31142
55
999
65
0
75
0
85
0
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS
% LAMP %LUMINAIRE
0-30
5842
30
70.25
0-40
7522
38.63
90.46
0-60
8315
42.7
100
0-90
8315
42.7
100
40-90
793
4.07
9.54
60-90
0
0
0
90-180
0
0
0
0-180
8315
42.7
100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%