Lightolier 1004F18ES 产品宣传页

下载
页码 1
Lightolier 
a Genlyte company 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • B0906
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
Lytecaster
®
 Recessed Downlighting 
1004F18ES
Page 1 of 1 
5" Aperture 
0
®
 1 Lt 18W Quad/Triple Tube Compact Fluorescent IC Frame-In Kit
Features
1.  Housing: .032" (#20 ga.) UL listed for direct contact with thermal insulation. 
Allows installation in ceilings up to 2" thick. Can be removed for access 
to junction box, ballast and ceiling plenum. AirSeal
®
 housing minimizes 
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with 
Model Energy Code (Section 602.3.3) and Washington State Energy Code 
(Section 502.4) and reduces heat loss and condensation in ceiling.
2.  Mounting Frame: .048” (#18 ga.) galvanized steel. Locks into position along 
length of mounting bars with locking spring and bendable slot. (3) slots 90° 
apart simplify alignment.
3.  Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel. 
UL listed for branch circuit wiring supplying connected luminaires.  Integral 
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex
®
 
cable without tools or additional connectors.
4.  Mounting Bars: .059” (#16 ga.) galvanized steel. Bars pivot for easy 
attachment and wire-in below ceiling line. Bars extend to accommodate 16" 
to 24" O.C. joist spacing. Bars can accommodate 9" O.C. joist spacing after 
a slight field modification (see Instruction Sheet). Features integral self-
tapping phillips screws for secure attachment to wood or metal construction. 
Attaches to T-bar ceilings without the need of accessories.
5.  Socket Housing: Trim retaining spring secures trim to any height on 
housing wall.
6.  Socket: (4 Pin,GX24q-2) base, molded thermo-plastic. Pre-wired with #18 
AWG leads to junction box.
7.  Ballast: Electronic 120V, end of life protected, FCC class “B” consumer 
limits, class “A” sound rating. Energy Star
®
 qualified.
Electrical
Input Watts: 19
Amps: .16
Ballast Factor: 1.0 
Power Factor: .97
Electrical (cont.)
Max THD %: 10
Min Start Temp: 0˚F/ -18˚C
Options & Accessories
AirSeal
®
 Kit: LAS56 (optional)
Note: Use only if factory installed tape or knockouts are removed from vertical 
adjustment slots in housing wall.
Labels
UL (Type IC Suitable for Damp Locations)
Complies with Air Leakage Requirements stated in the Model Energy Code,  
California Title 24 and the Washington State Energy Code.
Romex
®
 is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
13" MIN. 
24" MAX. 
9" 
OVERALL 
LENGTH 
5 3/4" 
OVERALL 
WIDTH 
5" 
APERATURE 
7 1/2" 
OVERALL 
HEIGHT 
Ceiling Opening 5 3/8" diameter
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Voltage
Lamp
Open Downlight
  Enclosed  
  Diffusers
  Wall  
  Washer
Anodized
 
Reflector Anodized
 
Cone
Satin Cone
Baffles
Basic White
1004F18ES
1004F18ESN
120V
18W 
Quad or 
Triple 
Tube
1045
1046
1046CD
1012
1012NM
1013
1013BK
1013BKNM
1013CD
1013CDNM
1013NM
1013WH
1008
1008NM
1010
1010NM
1005
1005BNM
1005NM
1005WH
1076
1076WH
1071
1021
1024
1078
1177LX**
1035
1035WH
1085
1095
1096
1096CD
** Use Triple Tube Lamp Only.