Cooper Lighting MPWC 用户手册

下载
页码 4
Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
04/15/2007 12:56:42 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADC041675
LAMP CONFIGURATIONS
MOUNTING DIMENSIONS
DESCRIPTION
Fail-Safe's MPWC series combines a multi-function, wall mounted fixture 
with contemporary styling. Through innovative features, the MPWC 
accommodates multiple applications throughout the healthcare 
environment. One fixture supplies the patient room with task lighting, 
offering practical solutions to the patient and medical staff for everyday 
tasks. The MPWC is separated into two compartments: up light for general 
ambient room lighting and down light for reading/direct task lighting to 
accommodate the needs of the patient or healthcare professional. The 
fixture is UL listed.
Application
The MPWC is designed for use in 
healthcare environments, 
specifically for use in patient 
rooms over beds to facilitate all of 
the tasks required by the patient 
and medical staff. The MPWC's 
aesthetics make it ideal for other 
applications such as over vanities, 
rest rooms, and hallways.
A ... Lens
Up light: .125" thick, prismatic K12 
pattern, acrylic lens is standard 
(prisms on the inside for ease of 
cleaning). Down light: .125" thick, 
prismatic K12 pattern, acrylic lens 
is standard (prisms inside).
B ... Fasteners
Nickel-plated thumbscrews are 
standard (requires no tools to 
remove lens assembly).
C ... Construction
Outer housing is 18 gauge, 
die-formed, cold rolled steel with 
seam-welded ends. Back pan 
housing is 20 gauge, die formed 
cold rolled steel. Power tray and 
reflector are 20 gauge cold rolled 
steel.
D ... Lamps
T8 Linear Fluorescent
T5 HO Linear Fluorescent
E ... Ballast  Options
T8 Electronic Instant Start
T5 Electronic Programmed Start 
T8 Magnetic-HPF
F ... Finish
High gloss white polyester powder 
coat finish is standard on exterior 
housing. A multistage cleaning and 
painting process is utilized. Interior 
reflector is high reflectance white, 
minimum reflectance 92%. Custom 
colors are available.
Labels
UL/cUL Listed for Damp Locations
MPWC
34W - 216W
Fluorescent
CONTEMPORARY
HEALTHCARE
WALL MOUNTED
LUMINAIRE
C     
D
E
B
A
6”
[153mm]
6 1/2”
[165mm]
1 7/8”
[47MM]
1 7/8”
[47MM]
1 7/8”
[47MM]
1 7/8”
[47MM]
24 3/8”[620mm]
36 3/8”[925mm]
22”[559mm]
34”[864]
20”[508mm]
8”[203mm]
6 1/16”
[154mm]
6 1/16”
[154mm]
6 1/16”
[154mm]
3/16 X 11/16”
[4.8 X 17.5mm]
Keyhole Mtg. Holes
3/16 X 11/16”
[4.8 X 17.5mm]
Keyhole Mtg. Holes
3/16 X 11/16”
[4.8 X 17.5mm]
Keyhole Mtg. Holes
2 1/4”
[57mm] Dia.
Access Hole
2 1/4”
[57mm] Dia.
Access Hole
2 1/4”
[57mm] Dia.
Access Hole
48 3/8”[1229mm]
46”[1168mm]
32”[813mm]
16”[406mm]
E N E R G Y   DATA  
Input Watts:
T5HO Fluorescent Lamps
Electronic Ballasts*
(2) 24W T5 HO Lamps: 54W
(3) 24W T5 HO Lamps: 79W
(4) 24W T5 HO Lamps: 104W
(2) 39W T5 HO Lamps: 80W
(3) 39W T5 HO Lamps: 127W
(4) 39W T5 HO Lamps: 174W
(2) 54W T5 HO Lamps: 124W
(3) 54W T5 HO Lamps: 182W
(4) 54W T5 HO Lamps: 240W
*Energy Data calculated using 
2 ballasts per each lamp
configuration. (Programmed start,
normal light output, average ballast
factor 0.95 to 1.1)
T8 Fluorescent Lamps
Electronic Ballasts*
(2) 17W T8 Lamps: 40W
(3) 17W T8 Lamps: 54W
(4) 17W T8 Lamps: 68W
(2) 25W T8 Lamps: 54W
(3) 25W T8 Lamps: 74W
(4) 25W T8 Lamps: 94W
(2) 32W T8 Lamps: 64W
(3) 32W T8 Lamps: 90W
(4) 32W T8 Lamps: 116W
*Energy Data calculated using 
2 ballasts per each lamp
configuration. (Instant start, normal
light output, average ballast factor
0.9 to 1.0)
FAIL-SAFE
®