Cooper Lighting IMI-695B 产品宣传页

下载
页码 1
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
NOTE: Use minimum 90°C supply wire rating for connections. 
WALL MOUNT ARM ACCESSORY (ENVOY PARKING LUMINAIRE) INSTALLATION: (Figure 1)
1. Affix wall mount arm on the wall with (4) four bolts (provided by others).
Note: Use RTV or liquid sealant to seal back of arm if necessary.
2. Remove quick mount plate from the luminaire and install it on the wall mount arm with provided #8-32 screws.  Quick mount plate will only mount in one
direction.  Align (2) bosses on arm with (2) slots on plate.
3. To install luminaire, secure hanging hook into the front hooks of quick mount plate.
4. Make wiring connections while luminaire is suspended on hanging hook.
5. Lift up luminaire onto the (4) four hooks of quick mount plate while guiding the wires through center access hole.
6. Pull luminaire forward for engagement. When it reaches the full-engaged position, a “CLICK” can be heard.
CAUTION: If full engagement is not reached, it is not yet rigidly installed.
7. Install arm cover with provided #10-24 flat head screws.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. 
NOTE: Specifications and dimensions subject to change without notice.
EPL/WM Envoy
Wall Mount Arm
Sheet 1 of 1
4/7/08
IMI-695B
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE 
GENERAL: Upon receipt of luminaire thoroughly inspect for any freight
damage, which should be brought to the attention of the delivery 
carrier. Compare the catalog description listed on the packing slip 
with the luminaire label on the housing to assure you have received the 
correct merchandise.
SAFETY: This luminaire must be wired in accordance with the national
electrical code and applicable codes and ordinance. Proper grounding 
is required to insure personal safety. Carefully observe grounding 
procedure. All work should be done by a qualified electrician.
WARNING: Make certain power is OFF before starting installation or
attempting any maintenance.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit
breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow luminaire to cool
before changing lamp or handling luminaire.
WARNING: This luminaire is for use with downlight application only.
WARNINGRISK OF FIRE! DO NOT mount on or near combustible 
materials.
Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    ADH080773
Figure 1
ARM BOSSES
FRONT HOOKS
WALL MOUNT ARM
MIN. 1/4” BOLT
(BY OTHERS)
ARM COVER
QUICK MOUNT
PLATE
#8-32 SCREW
LUMIINAIRE
HANGING HOOK
#10-24 FLAT HEAD
SCREWS
CENTER ACCESS HOLE
4.75
[120.6]
2.38
[60.5]
MOUNTING HOLE
PATTERN