Cooper Lighting C Series 产品宣传页

下载
页码 1
691
LIGHTING INVER
TERS
COOPER LIGHTING
COOPER LIGHTING - SURE-LITES
®
• Input 120 or 277VAC
1 phase 2 wire
• Custom voltages available
• Electronic and magnetic
ballast compatible
• Generator compatibility
• Forced air cooling only
during emergency 
operation, no filters 
required
• 90 minute runtime standard;
other runtimes available
upon request
• 98% efficient PWM/IGBT
technology with micro-
processor control
• User programmable with
password protection
• Self-Testing and Self-
Diagnostic with Event, Test
and Alarm Logs
• RS232 communications port
• UL 924 listed
LIFEWAY II
SINGLE PHASE
SERIES
1 . 5 - 1 6 . 7   K V A
H I D ,   F l u o r e s c e n t   a n d
I n c a n d e s c e n t
O N - L I N E   P O W E R  
I N V E R T E R   S Y S T E M S
D I M E N S I O N S
D E S C R I P T I O N
The Sure-Lites Lifeway II C
Series is a single phase
inverter that provides
uninterrupted power. This
pulse width modulated
inverter utilizes IGBT
technology and has a 2
millisecond transfer time. The
unit’s operating efficiency is
98%, well above a typical fast
transfer inverter. The C Series
inverter is UL 924 Listed and
meets NFPA 101 requirements
by providing 90 minutes of
illumination for emergency
egress lighting. Other run
times and voltages are
available. Please consult your
Cooper Lighting
Representative.
A
B
C
H e i g h t
W i d t h
D e p t h
A
B
C
47"
30"
25"
S P E C I F I C AT I O N   D AT A
Input Voltage
120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages.
Input Frequency
60Hz, ±3%
Input Protection
Input Circuit Breaker
Input Harmonic Distortion
<10%
Input Power Factor
0.5 lag/lead
Output Voltage
120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages.
Static Voltage
Load current change ±2%, battery discharge ±12.5%
Dynamic Voltage
±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3 
cycles
Output Harmonic Distortion
<3% THD for linear load
Output Frequency
60 Hz. ±0.05Hz during emergency mode
Load Power Factor
0.5 lag to 0.5 lead
Inverter Overload
125% for 5 minutes
Output Protection
Optional Distribution Circuit Breakers
Battery
10 Year Valve-regulated Sealed Lead Calcium (standard)
Environmental
Altitude
<10,000 feet without derating
Operating Temp.
System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating, 
20° to 30°C (68° to 86°F), includes battery performance wich can be affected by 
temperature. Contact factory for details.
Storage Temp.
-20° to 70°C (Electronics Only)
Humidity
<95% (non-condensing) 
L I F E W AY   I I   S I N G L E   P H A S E   C   S Y S T E M   PA R T   N U M B E R   /   R AT I N G   /   M E C H A N I C A L   S P E C I F I C AT I O N S
Part
Pwr Rtg Pwr Rtg
Effic.
Audible    Heat Loss             UPS Cabinet Dimensions
UPS
Battery
Battery
Battery  
Battery Cabinet Dimensions
No. of
Total
Total
Number
kVA
kW
@ full load
Noise
BTU
Width Height
Depth
Weight
Voltage
Current
Run
Width
Height
Depth
Battery
No. 
of
System
%
db@1m
in/cm
in/cm
in/cm
lb/kg
VDC
Amperes Minutes
in/cm
in/cm
in/cm
Cabinets Cabinets
Weight (lb/kg)
ISC015
1.5
1.5
98
45
75
30/77
47/120
25/64
250/114
48
39
90
na
2
na
2
na
2
na
2
1
546/249
ISC022
2.25
2.25
98
45
100
30/77
47/120
25/64
265/121
72
38
90
na
2
na
2
na
2
na
2
1
709/323
ISC030
3.0
3.0
98
45
160
30/77
47/120
25/64
295/134
96
38
90
na
2
na
2
na
2
na
2
1
887/403
ISC037
3.75
3.75
98
45
200
30/77
47/120
25/64
305/139
120
37
90
na
2
na
2
na
2
na
2
1
1045/475
ISC048
4.8
4.8
98
45
245
30/77
47/120
25/64
315/143
144
40
90
na
2
na
2
na
2
na
2
1
1203/546
ISC060
6.0
6.0
98
45
300
30/77
47/120
25/64
350/159
180
40
90
30/77
47/120
25/64
1
2
1670/759
ISC080
8.0
8.0
98
45
400
30/77
47/120
25/64
375/171
240
39
90
30/77
47/120
25/64
1
2
2087/949
ISC100
10.0
10.0
98
45
500
30/77
47/120
25/64
435/198
144
82
90
30/77
47/120
25/64
2
3
2631/1195
ISC125
12.5
12.5
98
45
660
30/77
47/120
25/64
465/211
180
82
90
30/77
47/120
25/64
2
3
3105/1409
ISC167
16.7
16.7
98
45
840
30/77
47/120
25/64
530/241
240
80
90
30/77
47/120
25/64
2
3
3954/1795
O R D E R I N G   I N F O R M AT I O N
S A M P L E   N U M B E R :   I S C 0 3 7 1 2 0 1 2 0
Series
ISC
=Single
Phase C
Voltage Input
120
277
ISC
KVA Rating
Voltage Output
120
277
015=1.5
022=2.25
030=3.0
037=3.75
048=4.8
060=6.0
080=8.0
100=10.0
125=12.5
167=16.7
Options