Elkay EDFPA117FPC 用户手册

下载
页码 4
97729C (Rev. C - 1/04)
EDFPA117FPC, EDFPA117FPRAC
PAGE 4
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
DESCRIPTION
21705C
28322C
21810C
21822C
21823C
21845C
21846C
28227C
28229C
50198C
55001026
70002C
15009C
100322740560
45392C
70410C
70426C
75555C
*75559C
*72000833
75570C
56092C
75520C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NS
NS
PART NO.
CLIP-PUSH ROD
BRACKET-PUSH BAR MTG.
PUSH BAR ASSY
FTN BODY&SHELL EDFP110C
FTN BODY&SHELL EDFP114C
COVER PLATE EDFP110C
COVER PLATE EDFP114C
BACK PANEL EDFPA117FRC
BACK PANEL EDFPA117FPRAC
BUSHING-SNAP
BASIN
SCREW-#10 X .50 HHSM
NIPPLE ASSEMBLY
GASKET
BUBBLER
ROD-PIVOT
SCREW #8-32 X .25 THMS
CLIP -.125 STUD LOCK
PUSH ROD ASSY
WASTE ARM ASSEMBLY
SCREW-#10 X .50 PINNED TORX
POLY TUBING (CUT TO LENGTH)
BIT-PINNED TORX T-25
ITEM NO.
PARTS LIST
7, 20
SEE FIG. 5
SEE FIG. 6
4
8
16
15
2
17
9
3
11
1
FIG. 6
FIG. 5
18
* PARTS ARE SUPPLIED WITH FREEZE RESISTANT BOX
12
13
14
10
5
6, 20
19
FIG. 7
INSTALLATION INSTRUCTIONS
   1. Wall should already be framed for the fountain using
       the positioning dimensions shown in Figure 3 & 4.
       Shown dimensions pertain to installation location
      (framing must support up to 300 lbs. weight). These
       dimensions are required for compliance with ANSI
       Standard A117.1/ADA requirements.
  2. Install back panel. Place the upper edge of the panel
      above mounting plate on the wall. Slide the panel
      down until it engages the mounting plate. Be sure back
      panel is firmly engaged before releasing it.
   3. Remove bottom covers from fountains and save the
      screws. Assemble push rods to fountains. See Fig. 5.
     (Push rods provided with freeze-resistant boxes).
  4. Secure the fountains to the wall. Install the fountains
      to the back panel using (2) bolts and washers
      (provided) per each fountain. Next secure the fountain
      bodies to the back panel using (4) bolts and washers
      (provided) per each fountain. Tighten securely.
   5. Attach drain tubes (supplied with freeze-resistant
      box) to fountains and cut to required length using
      freeze resistant box as a guide.
    6. Install freeze-resistant box - see box instructions.
  7. Install a service stop (not provided) and make water
      supply connection from the stop to the strainers in
      the freeze-resistant box.
    8. Connect fountain water line to freeze-resistant
       box - see box instructions. Replace bottom covers.