2.7. Control 
Specifications 
The controller (GC-201, GC-101) is operated by: 
•  RS-232C command input 
• High-speed 
serial 
communication 
In addition, either the internal clock or external clock (high-speed serial communication) can be 
selected for operation. 
 
 Internal 
Clock 
External Clock 
(High-speed serial communication) 
Clock input 
Clock pulses generated by the 
controller internal circuit 
High-speed serial communication 
clock pulses 
Target position 
command 
RS-232C command 
High-speed  serial  communication 
command 
 
(When RS-232C command input 
mode is set, a high-speed serial 
communication command is 
ignored.) 
Operation setting 
parameter setting 
RS-232C command 
RS-232C command 
 
 
 
 
With the default settings at shipping, power-on activates the controller with the internal clock. 