Canon GC-251 用户手册

下载
页码 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
18
Parameter of controller can be changed by the following sending method to controller. 
Also in response to parameter send, the controller always returns a reply with data. 
The data contents depend on the command.    (For details, see 7-2, “Command Details.”) 
When changed a parameter of it, to start it by the same setting in power supply on at the next 
time; the parameter that changed, it is necessary to write in it at ROM. 
 
        Parameter send 
     
A        Axis
 No.        P        Command ID        /        Data          Delimiter 
 
 
 
 
 
 
 
         
E.g.  LQ gain parameter  ID = 6    Data = 4500 
           A1P006 / 4500 (LF) 
                            (ASCII code: 0x41 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a) 
                                                      A        1        P      0        0        6        /      4          5        0      0      (LF) 
 
 
   Parameter reply 
     
A        Axis
 No.        P        Command ID        /        Data          Delimiter 
 
 
 
 
 
 
 
         
E.g.  LQ gain parameter  ID = 6    Data = 4500 
           A1P006 / 4500 (LF) 
                            (ASCII code: 0x41 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a) 
                                                      A        1        P      0        0        6        /        0      (LF) 
 
 
 
Axis No. 
1 or 2 
Command ID 
Decimal, 3-digit 
(See 7-1 for details)
Parameter setting 
Decimal 
Parameter 
Delimiter
LF or CR 
Axis No. 
1 or 2 
Command ID 
Decimal, 3-digit 
(See 7-1 for details)
Parameter setting 
successful / unsuccessful 
0 or 1 
Parameter 
Delimiter
LF or CR