Parameter ID 
10 
Parameter 
Name 
Encoder Periodicity 
Data 
Encoder periodicity (Unit: pulse) 
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to set the number of pulses per rotation of the motor encoder. 
KP-1SM30,KP-1SM100: 83328 pulses 
Whenever the motor model is changed, the setting of this parameter should be 
changed. 
Related 
Command 
/Parameter 
 
 
Parameter ID 
11 
Parameter 
Name 
Sampling Time 
Data 
Sampling period (Unit: ns) 
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to set the sampling interval of the controller. 
The usual value is 10000 for 10 μs. 
Note: This parameter usually requires no change. 
Related 
Command 
/Parameter 
 
 
Parameter ID 
12 
Parameter 
Name 
Origin Clearance Timing (Head 1) 
Data 
Origin clearance timing (0 or 1) 
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is related to origin detection. 
The value checked by “Command ID = 101: Counter Clear Timing” is set. 
Each motor has a unique value. 
Note: An appropriate value is set at shipping. When only the motor is replaced, the 
value should be checked and set by a command. 
The Origin Clearance Timing (Head 2) parameter should be set at the same time. 
Related 
Command 
/Parameter 
Counter Clear Timing (Command ID = 101) 
      A1C101/ 0 (Axis 1 Head 1) 
Set the value checked above.