Lamp/Temperature/Filter Indicators
ENGLISH - 143
Maintenance
Temperature indicator<TEMP>
Indicator 
status
Lighting in red
Flashing in red
(2 times)
Flashing in red
(3 times)
Status
Warm-up status
Internal 
temperature 
is high. 
(WARNING)
Internal temperature is high 
(standby mode)
The cooling fan has 
stopped.
Cause
 
z
Did you turn on the 
power when the 
room temperature 
was about 0°C 
(32°F)?
 
z
Is the air intake/exhaust port blocked?
 
z
Is the room temperature high?
 
z
Is the filter indicator <FILTER> not lit?
Solution
 
z
Wait at least five 
minutes in the 
current status.
 
z
Install the unit 
in a location 
with an ambient 
temperature of 
0°C (32°F) to 45°C 
(113°F)
*1
.
 
z
Remove any objects that are blocking the air 
intake/exhaust port.
 
z
Move the projector to a location with an 
ambient temperature of 0°C (32°F) to 45°C 
(113°F)
*1
 and a humidity of 20% to 80% (no 
condensation).
 
z
Clean the air filter unit or replace it. (
 page 144)
 
z
Turn the <MAIN 
POWER> switch to 
<OFF> (
 page 51), 
and consult your 
dealer.
*1:  When using the projector at high elevations (1 400 m (4 593 ft) – 2 700 m (8 858 ft) above sea level), the operating environment 
temperature will be 5°C (41°F) lower than the maximum limit. The upper limit of the operating environment temperature will be 
reduced by a further 5°C (41°F) when using the replacement lamp unit (for portrait mode).
When using a smoke cut filter, the temperature will be 0°C (32°F) to 35°C (95°F). However, it cannot be used at high elevations.
Note
 
z
If the temperature indicator <TEMP> is still lit or flashing after taking the preceding measures, ask your dealer 
to repair the unit.
Filter indicator <FILTER>
Indicator 
status
Lighting in red
Flashing in red
Status
The filter is clogged.
The temperature inside or outside the projector is abnormally high.
The air filter unit is not 
attached.
Cause
 
z
Is the air filter unit 
dirty?
 
z
Is the air intake/
exhaust port 
blocked?
 
z
Is [HIGH ALTITUDE 
MODE] set 
correctly?
 
z
Is the air filter unit 
attached?
Solution
 
z
Clean the air filter 
unit or replace it. 
(
 page 144)
 
z
Remove any objects 
that are blocking the 
air intake/exhaust 
port.
 
z
When using the 
projector at high 
elevations 1 400 m 
(4 593 ft) – 2 700 m 
(8 858 ft) sea 
level, set [HIGH 
ALTITUDE MODE] 
(
 page 100) to [ON].
 
z
Do not use the 
projector at high 
elevations 2 700 m 
(8 858 ft) or higher 
above sea level.
 
z
Attach the air filter 
unit.
Note
 
z
If the filter indicator <FILTER> is still lit or flashing after taking the preceding measures, ask your dealer to 
repair the unit.
 
z
If the filter is clogged, only one lamp may light even when [LAMP SELECT] is set to [QUAD], [TRIPLE], or 
[DUAL]. Cleaning the air filter unit or replacing it with a new one will turn off the indicator.