LAMP/TEMP/FILTER Indicators 
88 - ENGLISH
Maintenance
 
Temperature indicator <TEMP>
Lamp 
indication
Lighting in red
Blinking in red
(once)
Blinking in red
(3 times)
Status
Warm-up status
Internal temperature is 
high. (WARNING) 
Internal temperature 
is high. (Standby 
condition) 
The cooling fan has 
been stopped. 
Points to be 
checked
 
z
Did you turn on 
the power when 
the ambient 
temperature was 
lower than approx. 
0°C (32°F)? 
 
z
Is the ventilating port (intake/exhaust) 
blocked?
 
z
Is the room temperature too high?
 
z
Is the filter indicator <FILTER> lit?
Remedial 
measure
 
z
Wait about five 
minutes in the 
current status. 
 
z
Install the unit in 
a location with an 
ambient temperature 
from 0°C (32°F) - 
45°C (113°F)
*1
 
z
Remove any objects that are blocking the 
ventilating port (intake/exhaust). 
 
z
Move the projector to a temperature of 0°C 
(32°F) - 45°C (113°F) 
*1
 and the humidity of 
20% to 80% (no condensation). 
 
z
Set the <MAIN 
POWER> switch to 
<OFF> (
 page 35), 
and consult your 
dealer.
*1:  When using the projector at high elevations 1 400 m (4 593 ft) – 2 700 m (8 858 ft) sea level, the temperature will be 5°C (41°F) 
lower than this higher limit.
Note
 
z
If the temperature indicator <TEMP> is still lighting or blinking after taking the preceding measures, ask your 
dealer to repair the unit. 
 
z
If the projector is used with the following two settings when the ambient temperature reaches 40°C (104°F) (35°C 
(95°F) in [HIGH ALTITUDE MODE]) or above, the light output may decrease by 20% to protect the projector. 
– [LAMP SELECT] is set to [DUAL] in the menu
– [LAMP POWER] is set to [HIGH] in the menu
 
Filter indicator <FILTER>
Lamp indication
Lighting in red
Blinking in red
Status
The filter is clogged. 
The ambient temperature or the internal temperature is extremely high.
The air filter unit is 
not attached. 
Points to be 
checked
 
z
Is the air filter 
unit dirt? 
 
z
Is the ventilating 
port (intake/
exhaust) blocked?
 
z
Is [HIGH ALTITUDE 
MODE] set correctly?
 
z
Is the air filter 
unit attached? 
Remedial 
measure
 
z
Clean the air filter 
unit. (
 page 89)
 
z
Remove any 
objects that are 
blocking the 
ventilating port 
(intake/exhaust).
 
z
When using the projector 
at high elevations 1 400 m 
(4 593 ft) – 2 700 m 
(8 858 ft) sea level, set 
[HIGH ALTITUDE MODE] 
(
 page 61) to [ON].
 
z
Do not use the projector 
at high elevations 2 700 m 
(8 858 ft) or higher sea 
level. 
 
z
Attach the air 
filter unit. 
Note
 
z
If the filter indicator <FILTER> is still lighting or blinking after taking the preceding measures, ask your dealer to 
repair the unit. 
 
z
If the air filter unit is not attached when the power is turned on, the filter indicator <FILTER> will blink in red and 
the power will turn off after ten minutes.
 
z
If the filter is clogged, only one lamp may light even when [LAMP SELECT] is set to [DUAL]. Clean the air filter 
unit or replace with new one.