Signature Cinema™ SC-50d/SC-60d Installation/Operation Manual
65 
L
IMINAR
Y
Use the Calibration menu to perform advanced picture quality adjustments. This menu 
should be used by ISF-certified technicians only. 
To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the 
Memory Presets menu (see page 62) or use the corresponding remote control buttons. 
Display Color: Use the Display Color settings to adjust the color balance at the DHD 
Controller output. These settings are saved independently for each input and display 
mode.
• Gain: Use the Gain controls to correct color imbalances in the bright areas of the 
image. A good way to do this is to use a test pattern consisting mostly of solid white 
areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red (Pr), 
green (Y) or blue (Pr), decrease the Gain for that color.
• Offset: Use the Offset controls to correct color imbalances in the dark areas of the 
image. A good way to do this is to use a test pattern consisting mostly of dark gray 
areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red (Pr), 
green (Y) or blue (Pr), decrease the Offset for that color.
• GammaSelect Gamma from the Display Color menu to choose a de-gamma curve. 
Used correctly, the Gamma control can improve contrast while maintaining good 
details for blacks and whites. If excess ambient light washes out the image and it 
becomes difficult or impossible to see details in dark areas, lower the gamma setting to 
compensate. This improves contrast while maintaining good details for blacks. 
Conversely, if the image is washed out and unnatural, with excessive detail in black 
areas, increase the setting. 
• Mode: With the SC-50d/SC-60d, two Gamma adjustment modes are available: 
Simple or Advanced. The two modes are mutually exclusive; when you select the 
Simple mode, the Advanced selection in the Gamma menu is grayed out. Likewise, 
when you select Advanced, the Simple selection is grayed out.
• Simple: Use the Simple Gamma control to perform gamma correction at the display 
according to a simple power law gamma function. The value chosen here 
corresponds to the power variable in this equation:
Output = Input
Power
The DHD Controller applies this gamma curve to all three primary color channels 
(red, green and blue). 
• Advanced: To select a custom gamma curve, select Mode from the Gamma men
and set it to Advanced. Then, select Advanced from the Gamma menu to select one 
of up to 20 pre-programmed gamma tables. Custom gamma tables provide the 
ability to perform complex, non-linear gamma correction on each primary color 
channel independently of the others.
ISF Settings
You must enter a passcode to access the Calibration menu. 
Note