Runco LS-100d 用户手册

下载
页码 114
Lightstyle™ Series LS-100d Installation/Operation Manual
73 
PRE
L
IMINAR
Y
Display Blue Gain
DBG
R/W
Yes
-100
100
No
Display Blue Offset
DBO
R/W
Yes
-100
100
No
Default Gateway Byte 1
DE1
R/W
Yes
0
255
No
Default Gateway Byte 2
DE2
R/W
Yes
0
255
No
Default Gateway Byte 3
DE3
R/W
Yes
0
255
No
Default Gateway Byte 4
DE4
R/W
Yes
0
255
No
Diagnostic Color
DGC
R/W
No
0
6
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
Display Green Gain
DGG
R/W
Yes
-100
100
No
Display Green Offset
DGO
R/W
Yes
-100
100
No
DHCP
DHC
R/W
No
0
1
No
0 = Off; 1 = On
Display Red Gain
DRG
R/W
Yes
-100
100
No
Display Red Offset
DRO
R/W
Yes
-100
100
No
Error Notification
ERN
R/W
No
0
1
No
0 = Off; 1 = On
Error Code
ERR
R
No
0
No
0 = None
1 = Display Lamp Overtemp
2 = Display Ballast Overtemp
3 = Display Fan Init Failure
4 = Display Fan 1 Failure
5 = Display Fan 2 Failure
6 = Display Fan 3 Failure
7 = Display Fan 4 Failure
8 = Display Fan 5 Failure
9 = Display Fan 6 Failure
10 = Display Fan 7 Failure
11 = Display Fan 8 Failure
12 = Display DMD Failure
16 = Display GPIO Failure
18 = Display Processor Failure
19 = Display Hardware I2C Failure
20 = Display Software I2C Failure
22 = Display Communication Error
25 = DHD Fan 1 Failure
26 = DHD Fan 2 Failure
27 = DHD Overtemp 1
28 = DHD Overtemp 2
Film Mode
FLM
R/W
No
0
1
No
0 = Off; 1 = On
Fan 1 Speed
FN1
R/W
Yes
0
255
No
Table 6-1. Serial Commands (continued)
Setting
Command 
Code
Read/
Write
Inc/
Dec
Min 
Value
Max 
Value
String?
Notes