MAINTENANCE-SHUNT ADJUSTMENT 
86306300 CHARIOT BURNISHER  11/09/07 
4-10 
SHUNT ADJUSTMENT 
 
This pad pressure meter adjustment is factory set.  
Over the course of time it may become necessary to 
adjust this setting using the slotted connection on 
the shunt. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check the amp range when nuisance tripping of the 
pad motor controller indicates that the shunt may be 
out of adjustment. 
 
 
1.  Connect a DC ampere meter to the positive 
battery lead. Running the machine with a pad, 
lower the pad to the floor until it is operating at 
60
±5 amps. 
 
2.  Moving the wire in the slot, adjust the pad 
pressure meter until the needle sets at the line 
between the blue and red areas. 
APPROX. AMP RANGE
60
0
RED
GREEN
GREEN