Wiring the 9739 MVD transmitter to the sensor
Table 4-6
Bend radii of shielded cable
Minimum bend radii
Jacket material
Outside diameter
Static (no load) condition
Under dynamic load
PVC
0.2 inches (14 mm)
4–1/4 inches (108 mm)
8–1/2 inches (216 mm)
Teflon FEP
0.425 inches (11 mm)
3–1/4 inches (83 mm)
6–3/8 inches (162 mm)
Table 4-7
Bend radii of armored cable
Minimum bend radii
Jacket material
Outside diameter
Static (no load) condition
Under dynamic load
PVC
0.525 inches (14 mm)
4–1/4 inches (108 mm)
8–1/2 inches (216 mm)
Teflon FEP
0.340 inches (9 mm)
3–1/4 inches (83 mm)
6–3/8 inches (162 mm)
Cable illustrations
Figure 4-9
Cross-section view of jacketed cable
A
C (4)
B (4)
D (5)
A
Outer jacket
B
Drain wire (4 total)
C
Foil shield (4 total)
D
Filler (5 total)
Installation Manual