Raypak 926-1758 产品宣传页

下载
页码 2
Catalog No.:  2000.22N 
Effective:  12-1-07 
Replaces:  10-15-03
 
Job: 
 
           
 
Engineer: 
 
           
 
Contractor: 
 
           
 
Prepared By: 
            
 Date: 
            
 
Model: 
  
           
 
 
 
 
EFFICIENT 
 82% thermal efficiency – highest of any atmospheric 
boiler available today 
THERMAL SHOCK PROOF 
 Twenty-year warranty against thermal shock damage 
up to 150°F differential 
 Maximum operating temperature: 230°F 
LIGHTWEIGHT 
 A floor load of 70 lbs./sq. ft. or less 
HIGH RECOVERY 
 Cuts fuel costs substantially because the standby and 
radiation losses normal to other boilers are eliminated 
LOW WATER OPERATING TEMPERATURE 
 Operates with water temperature as low as 105°F 
without condensing 
 
Heat Exchanger 
ƒ  ASME Inspected and Stamped 
160 PSIG 
ƒ  National Board Approved 
ƒ Headers 
 Glass-lined Cast Iron – Standard  
 Bronze – Option A-1 
ƒ Finned 
Tubing 
 Copper – Standard  
 Cupro Nickel – Option A-3  
ƒ  ASME Steel Tube Sheet 
ƒ Silicone 
O-Rings 
ƒ  60 PSIG ASME Pressure Relief Valve 
ƒ  Temperature and Pressure Gauge 
(Boiler) 
ƒ Water 
Connections 
 Left Hand – Standard  
 Right Hand – Option A-6  
ƒ Flow 
Configuration 
 Two-pass – Standard  
 Single-pass (Cast Iron Only) 
ƒ  Pump, Rear-mounted (Optional) 
 4.25” Impeller 
 4.7” Impeller  
Controls 
ƒ  120V, 60Hz, 1 Ph Power Supply 
ƒ 120/24V 
Transformer 
ƒ  100% Pilot Shut-off/Lockout 
ƒ  Electronic, Intermittent Ignition (IID) 
Pilot 
ƒ  High Limit Control, Manual Reset 
Controls (cont.) 
ƒ On/Off 
Switch 
ƒ Flow 
Switch 
ƒ  Economaster II Pump Time Delay 
 
Gas Control Train 
ƒ  Manual Main Gas Shut-off Cock 
ƒ  Main Gas Pressure Regulator 
ƒ  Redundant Safety Shut-off Valve 
ƒ  Control Valve         
ƒ Firing 
Mode 
 On/off (H4) 
 Two-stage Firing (H3) 
 Four-stage Firing (H9) 
 Mechanical Modulation, 
110-170°F (H5) 
 Mechanical Modulation,  
150-210°F (H1) 
 Motorized Modulation (H2) 
 B-6000 (H6) 
ƒ Fuel 
 Natural Gas 
 Propane Gas     
ƒ  Design Certified ANSI Z21.13/CSA 4.9 
Construction 
ƒ Front 
Controls 
ƒ  Stainless Steel Burners 
ƒ  Polytuf Powder Coat Finish 
ƒ Stackless 
Top 
ƒ Base 
(Optional) 
 Combustible Floor Shield – Option J-1 
 
 
Temperature Controllers 
Note:  H1 and H5 do not require a controller 
 B-7 
Modulating 
 B-5 
Modulating, Outdoor Reset 
 B-6 
Two-stage 
 B-    Four-stage Digital 
 Y-241 Electronic Sequencer,  
1-4 Stages 
 
 Y-281 Electronic Sequencer,  
1-8 Stages 
Additional Safety Controls 
 F-9 
Low Water Cut-off Probe 
 I-1 
High Limit Control,  
Auto Reset 
 S-1 
Low Gas Pressure Switch 
 S-2 
High Gas Pressure Switch 
                       
 
                       
 
Regulatory Agency Requirements 
            
 
            
 
 
Raytherm
®
 
- Type H
Hydronic Heating Boilers
Commercial
Models 926-1758 (Outdoor)
Fig. #8953