Raypak 992BE-2342BE 产品宣传页

下载
页码 2
Catalog No.:  2000.451E 
Effective:  11-15-07 
Replaces:  1-1-07 
Hi Delta – Type H 
Models 992BE-2342BE, 87% Efficiency 
Model            
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SPECIFICATIONS 
 
 
 
 
Approx. 
 MBTUH 
Firing
A
H
K
T
W
Amp.
Shipping 
Model Input Output Stages Width NPT    
 
Draw* Wt. 
(Lbs.) 
992BE 990
861 
57-1/8
2-1/2
10 10
16-13/16
<12
900 
1262BE 1260  1096 
68-1/2  2-1/2
12 10
20-9/16 
<12 1010 
1532BE 1530  1331 
79-7/8  2-1/2
12 10
24-3/8 
<12 1225 
1802BE 1800  1566 
91-1/8  2-1/2
14 10
28-1/8 
<12 1350 
2002BE 1999  1739 
102-1/2 2-1/2
14 10
31-15/16 
<12 1450 
2072BE 2070  1801 
102-1/2 2-1/2
14 10
31-15/16 
<12 1450 
2342BE 2340  2036 
113-7/8 2-1/2
16 10
35-11/16 
<12 1520 
Dimensions are in inches. 
* Without pump 
RATES OF FLOW AND PRESSURE DROPS 
 
20°F 
T
30°F 
T
Min. Flow 
Max. Flow
Model GPM
P (ft) GPM P (ft) GPM  P (ft)  T  GPM P (ft) T
992BE
86
6.0
57
2.7
43 1.6 40 
132
14.0
13
1262BE
110
10.7  73  4.9  55  2.8  40 132 15.5 17 
1532BE
132
16.5 
 89  7.6  67  4.4  40 132 16.5 20 
1802BE
N/A
N/A 
 104
11.6 78  6.5 40 132 18.0 24 
2002BE
N/A
N/A 116
15.1 87  8.7 40 132 19.5 26 
2072BE
N/A
N/A 
 120
16.2 90  9.3 40 132 19.5 27 
2342BE
N/A
N/A 
 N/A
N/A  102 13.0 40 132 21.0 31 
Basis is 30 GPM or 40°F 
∆T for minimum flow, 132 GPM for maximum flow. 
NOTE:  Pump location 
varies based on model 
and application. 
NOTES:  1.  Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 
 
2.  Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 – 13” WC.
 
Raypak, Inc.  
ƒ  2151 Eastman Avenue, Oxnard, CA  93030  ƒ  (805) 278-5300  ƒ  Fax (800) 872-9725  ƒ  www.raypak.com