RV53i & RV53e Operation and Installation Manual 
29 
  High 
Altitude 
Installations 
    
 
 
 
 
 
 
 
 
 
 
 
 
 
0-2000 ft 
(0-610 m) 
2001-5200 ft 
(610-1585 m) 
5201-7700 ft 
(1585-2347 m) 
7701-10200 ft 
(2347-3109 m) 
Switch No. 2 
OFF 
OFF 
ON 
ON 
Switch No. 3 
OFF 
ON 
OFF 
ON 
 
 
 
 
 
 
 
 
 
 
 
 
Set switches 2 and 3 to the values shown in table 
below for your altitude.  The default setting for the 
appliance is 0-2000 ft (0-610 m) with switches No. 2 
and No. 3 in the OFF position. 
  Connecting Multiple Water Heaters   
 
 
 
 
 
 
 
 
 
 
 
 
The RV53i can use the EZConnect™ cable which 
is an optional accessory that connects 2 water 
heaters and allows them to function as one hot 
water source.  
The RV53i can use the MSA-2M and MSA-2S 
packs which are optional accessories that connect 
2 to 5 water heaters and allow them to function as 
one hot water source. 
The RV53e cannot use the EZConnect, MSA-2MB, 
and MSA-2S.  The RV53e can use Rinnai pressure 
activation valves (PVA’s) can be used to manifold 2 
to 5 Rinnai water heaters in order to produce a 
stable water temperature and allow the water 
heaters to run efficiently.  Water heaters will turn 
on as necessary to meet the demand for hot water.  
Refer to the instructions that come with the 
accessory for complete installation information. 
Number of 
Connected 
Water Heaters: 
Accessories Necessary: 
(1) EZConnect™ Cable 
or
 
(1) MSA-2M 
(1) MSA-2M 
and
 (1) MSA-2S 
(1) MSA-2M 
and 
(2) MSA-2S 
(1) MSA-2M 
and 
(3) MSA-2S 
Guidelines 
•  Do not install both the EZConnect™ and the MSA packs because they are not designed to operate together. 
•  Water heaters connected with the EZConnect™ Cable or the MSA-2M and MSA-2S packs cannot be used for 
the bath fill function. 
•  Water heaters should be installed less than 18 inches apart so that the cables will reach between units and to 
prevent temperature fluctuations (cold water sandwich effect) when the water is shut off and turned back on. 
•  Temperature settings can only be changed on the controller for the primary unit.  (This changes the 
temperature on all units within the MSA or EZConnect™ system.) 
     WARNING 
DO NOT adjust the other 
switches unless specifically 
instructed to do so. 
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2