Rinnai RU80E 产品宣传页

下载
页码 2
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 
MC-91-2 (included) 
Deluxe controller: MC-100V-1US (optional) 
Bathroom controller: BC-100V-1US (optional) 
MCC-91-2 (optional; for hydronic and commercial applications) 
Non-polarized two-core cable, minimum 22 AWG 
•  Flame failure - Flame Rod 
•  Boiling protection  
•  Combustion fan rpm check 
•  Over current - glass fuse 
•  Top of heater - 12 inches 
•  Front (Panel) - 24 inches 
•  Front (Exhaust) - 24 inches 
•  Top of heater - 2 inches 
•  Front (Panel) - 0 inches * 
•  Front (Exhaust) - 24 inches 
Natural Gas:  min 5”  W.C. 
max 10.5”  W.C. 
Propane Gas:  min 8”  W.C. 
max 13.5”  W.C. 
Natural Gas:  high fire 1.9”  W.C.  low fire 0.46”  W.C.  
Propane Gas:  high fire 2.1”  W.C.   low fire 0.50”  W.C. 
Complies with South Coast Air Quality Management District 14 ng/J or     
20 ppm NOx emission levels 
DIMENSIONS 
WEIGHT: 70.5 lb (32 kg) 
 
Controller 
 
 
 
Controller Cable 
Safety Devices 
 
 
 
Clearances from Combustibles 
 
 
Clearances from Non-combustibles 
* 24 inches required for serviceability 
 
Min. / Max.  Gas Supply Pressure 
 
Manifold Gas Pressure (inches W.C.) 
 
NOx 
•  Remaining flame (OHS) 
•  Thermal fuse  
•  Automatic frost protection 
 
•  Back of heater - 0 inches 
•  Bottom of heater - 12 inches 
•  Sides of heater - 6 inches 
•  Back of heater - 0 inches 
•  Bottom of heater - 2 inches 
•  Sides of heater - 1/8 inch 
DIM Inches 
(mm) 
A (GAS) 
1.6 (40.2) 
A (COLD) 
2.0 (50.2) 
A (HOT) 
1.6 (41.2) 
A (CONDENSATE 
OUTLET) 
0.9 (22.4) 
B 5.0 
(127.2) 
C 1.9 
(47.8) 
D 0.52 
(13.3) 
10.1 (257.5) 
28.4 (721.
6)
 
25.7 (654
8.7 (222) 
0.4 (10.1) 
0.6 (15) 
18.5 (470) 
10.0 (253.8) 
0.6 (15)
 
2.0 (50)
 
 
RU80e (KB2530WD)  
DIM Inches 
(mm) 
E 2.2 
(56.3) 
F 2.3 
(58.3) 
G 5.0 
(127.2) 
H 2.0 
(50) 
I 3.0 
(76) 
J 7.1 
(179) 
K 18.3 
(466) 
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for 
commercial; All other parts: 5 years*; Labor: 1 year;  
(* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in 
series with a circulation system and all circulating water flows through the water heater, and where an 
aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) 
Refer to the manual for complete warranty information. 
Limited  
Warranty