RC80i (KA2530FFUD)  
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us 
MC-91-1US (included) 
Deluxe controller: MC-100V-1US (optional) 
Bathroom controller: BC-100V-1US (optional) 
MCC-91-1US (for commercial applications) 
Non-polarized two-core cable, minimum 22 AWG 
•  Flame failure - Flame Rod 
•  Boiling protection 
•  Combustion fan rpm check 
•  Over current - glass fuse (3 amp) 
•  Top of heater - 6 inches 
•  Front of heater - 6 inches * 
•  Sides of heater - 2 inches 
•  Top of heater - 2 inches 
•  Front of heater - 6 inches * 
•  Sides of heater - 1/2 inches 
Natural Gas:  min 5”  W.C. 
max 10.5”  W.C. 
Propane Gas:  min 8”  W.C. 
max 13.5”  W.C. 
Natural Gas:  high fire 2.9”  W.C.  low fire 0.70”  W.C.  
Propane Gas:  high fire 3.7”  W.C.   low fire 1.06”  W.C. 
Meets California and Texas NOx Emission Rules 
Heat exchanger: 12 years* for residential and 5 years* for commercial and 
hydronic applications; (10 years* if used with the Rinnai Hydronic Air 
Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a 
circulating water heater within a circulation loop, when the water heater is 
in series with a circulation system, all circulating water flows through the 
water heater and without an on-demand recirculation system).  Refer to 
the manual for complete warranty information. 
DIMENSIONS 
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 
•  Remaining flame (OHS) 
•  Thermal fuse 
•  Automatic frost protection 
 
•  Back of heater - 0 inches 
•  Bottom of heater - 12 inches 
•  From vent pipe - 0 inches 
•  Back of heater - 0 inches 
•  Bottom of heater - 12 inches 
•  From vent pipe - 0 inches 
WEIGHT: 63.9 lb (29 kg) 
 
Controller 
Controller Cable 
Safety Devices 
 
 
 
Clearances from Combustibles 
* 24 inches required for serviceability 
 
Clearances from Non-combustibles 
* 24 inches required for serviceability 
 
Min. / Max.  Gas Supply Pressure 
 
Manifold Gas Pressure (inches W.C.) 
 
NOx 
Warranty 
DIM DESCRIPTION 
in (mm) 
A Width 
18.5 
(470) 
Depth  
10.5 (266.9) * 
Height - Unit 
26.4 (670) 
Height - with brackets 
28.5 (723.2) 
Hot Water Outlet - from wall  
4.3 (110) * 
Hot Water Outlet - from center 
3.9 (100) 
Cold Water Inlet - from wall  
2.9 (74.6) * 
Cold Water Inlet - from center 
1.1 (27.7) 
Gas Connection - from wall  
3.9 (99) * 
Gas Connection - from center 
4.1 (103.2) 
K   
From base to gas connection 
1.6 (40.2) 
From base to cold connection 
2.0 (50.2) 
From base to hot connection 
1.6 (41.2) 
Condensate Dain - from wall  
5.2 (132.6) * 
M  Condensate Drain - from center 
7.7 (195) 
* This is the minimum 
dimension from the wall.  
The wall bracket is 
adjustable to allow an 
additional 1.57 inches (40 
mm). 
 
L E
M
F
H
J