V53i & V53e Operation and Installation Manual 
  Features Available on Temperature Controllers 
                 
Operating Instructions 
The V53i and V53e models do not come with a temperature controller.  There are several models of temperature 
controllers that can be purchased separately.  Their description, operation, and installation are provided in this 
manual in case a temperature controller is purchased and installed. 
A maintenance display or status monitor is provided in the front panel to indicate operating status and error codes.  
The temperature controllers below can be used with the V53i and V53e. 
 
Features 
MC-91 
MC-100 
BC
-10
MC-502
 
Description 
Call  
 
 
 
Sends a short series of beeps to all controllers in the system.  It is 
not an intercom.   
Clock  
 
 
 
 
12 hour AM/PM clock.  (The MC-100 must be installed for clock 
to work on the BC-100.) 
Function  
 
 
 
Used on this model to set the clock or sound volume. 
In Use Indicator 
 
 
 
 
Indicates that hot water is being supplied (i.e. a hot water tap is 
open). 
ON/OFF Button 
 
 
 
 
Used to turn the water heater ON or OFF. 
Power Save 
 
 
 
 
Allows the temperature controller to be in an energy saving 
mode. 
Priority Button / 
Indicator 
 
 
 
 
Indicates that this controller is setting the temperature .  Priority 
can be switched to another controller by pressing its Priority 
Button when no hot water is running. 
Sound Volume 
 
 
 
 
Used to adjust the voice prompt volume. 
Temperature Display 
 
 
 
 
Shows the temperature setting. 
Thermostat 
 
 
 
 
Increases or decreases the temperature setting. 
Water Smart / Bath Fill 
Button / Indicator 
 
 
 
 
Used to select the Water Smart / Bath Fill Function to fill a bath 
with a predetermined volume of water. 
Water Volume 
 
 
 
 
Used to select the water volume for the Water Smart / Bath Fill 
Function. 
MCC-91 
 
 
 
 
 
 
 
 
 
 
 
 
Error Codes 
 
 
 
 
 
When a fault is detected an error code flashes at the temperature 
display on models MC-91, MCC-91, and MC-502; and flashes at 
the clock display on models MC-100 and BC-100.