Rinnai V53I 用户手册

下载
页码 64
 
 
V53i & V53e Operation and Installation Manual 
  Temperature Controller Settings
                             
This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied 
or when more than 1 tap is in use.  The water heater can deliver water at only one temperature setting at a time.  
The available temperatures for a given model are provided below. 
Model 
Temperature Settings Available (ºF)  
V53i 
V53e 
98  100 102 104 106 108 110 115 120 125 
 130 135 140 
Temp in Celsius  ºC 
37 
38 
39 
40 
41 
42 
43 
46 
49 
52 
54 
57   60 
150
160
66 
71 
Suggested temperatures are 
•  Kitchen  120 ºF (49º C) 
•  Shower  98 - 110 ºF (37 - 43 ºC) 
•  Bath Fill  102 - 110 ºF (39 - 43 ºC) 
These temperatures are suggestions only. 
A temperature lower than 98 ºF (37 ºC) can be 
obtained at the tap by mixing with cold water. 
To change the temperature scale from Celsius to 
Fahrenheit or vice versa, press and hold the “On/Off” 
button for 5 seconds while the water heater is OFF. 
  Temperature Options Without a Temperature Controller   
         
The default temperature setting for this appliance 
installed without a temperature controller is 120º F 
(49º C).  If desired the temperature setting can be 
changed to 140º F (60º C) by adjustment of a switch. 
Set switch 5 to ON to obtain 140º F water temperature 
setting. 
Set switch 5 to OFF (default) to obtain 120º F water 
temperature setting. 
If a temperature controller is installed then switch 5 
has no effect on temperature settings. 
     WARNING 
DO NOT adjust the other 
switches unless specifically 
instructed to do so. 
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
120º F (49º C) 
140º F (60º C) 
*  MCC-91 Temperature Controller 
  These settings require the MCC-91 controller.  When the MCC-91 controller is connected, these higher 
temperatures are available on all controller models in the system.  
  Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial 
warranty application which is no coverage for these models (except when an MCC-91 is used with a Rinnai 
Hydronic Air Handler).  See the Warranty Information for more information on the warranty. 
  The MCC-91 controller is intended for commercial and hydronic applications only. If an MCC-91 controller is 
used in a residential dwelling for a hydronics application, a mixing valve must also be installed to limit the 
potable hot water temperature to a safe temperature. Water temperatures over 125º F (52º C) can cause 
severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be 
liable for damages resulting from such misuse or misapplication.