Rinnai Infinity 32e 用户手册

下载
页码 40
10
TECHNICAL DETAILS 
Infinity Model 
Infinity 32e 
HD70e
Units 
Installation
External
External
Nat Gas Press Low 
1.8 
1.8 
mbar
Nat Gas Press High
7.4 
7.4 
mbar
LPG Press Low 
3.5 
3.5 
mbar
LPG Press High
17.6 
17.6 
mbar
Height
600
600 mm
Width
470
470 mm
Depth
244
220 mm
Weight
29
29
kg
Flue System 
Temp. Range Controllers 
37
°
C -
40, 43, 50, 55*
60, 65, 75
40, 43, 50, 55
60, 65*, 75, 85
 55
°
C 37
°
C - 65
°
C deg 
Ignition
Direct Electronic Ignition
Gas Consumption Low
Nat Gas
5.7 
5.7 
kW
LPG
5
5.4
.4 kW
Gas consumption High
Nat Gas 
69
69
kW
LPG
69
69
kW
Max Flow raised 33C
24
24
L/min 
Min Operation Flow
2.4** 
L/min
Water Pressure Nom.
1.4 - 8.3 
bar
Power Supply
230 V / 50 Hz 
Electric Consumption
83
83
Watts 
Forced Exhaust 
Temp. Range without
Controllers
* Factory Setting
** Minimum operation flow based on temperature setpoint and
    inlet conditions.
deg C