installation diagrams - top inlet/outlet usage
Use of the top inlet water connection requires installation of an 
inlet dip tube (refer to figure 19). The tube is supplied in the 
heater. Follow caution labels if  applying heat to this fitting. Do 
not allow pipe dope to contact the plastic tube during installation.
tube inlet installation
figure 19
code restrictions
Use  of  the  top  inlet  water  connection  is  not  permitted  on 
installations in the state of North Carolina, due to the material 
of the tube (Polypropylene). Where such code restrictions exist, 
use only lower inlet tank connection. This may also require a 
heat  trap  -  check  local  codes.  The  “Top  Outlet”  connection 
may still be used on these applications. Plug or cap all unused 
openings in the tank before filling with water.
temperature setting should not exceed 
safe use temperature at fixtures. see water 
temperature control and mixing ValVe warning 
on page 12. if higher preheat temperatures are 
necessary to obtain adeQuate booster output, 
add an anti-scald ValVe for hot water supplied 
to fixtures.