Rheem RMTG-84DV 用户手册

下载
页码 36
   Required  adjustment  for  up  to  140°F  (60°C)  water  
temperature  settings  for  Residential  product  or  185°  
(85°  C).
!
WARNING:  Refer  to  scald  potential  warnings  on  
page  4  before  making  adjustment.  Changing  this  
setting  is  done  at  your  own  risk.
DO  NOT  execute  the  following  adjustment  if  the  
setting  of  up  to  140°F  (60°C)  is  not  required.
Follow  the  instructions  below  if  it  is  determined  that  a  
setting  of  up  to  140°F  (60°C)  is  required.  
●   
Turn  on  the  remote  control.  Turn  off  the  gas  and  
water  shutoff  valves.
●   
Press  the  UP  arrow  temperature  adjustment  
button  on  the  remote  control  for  several  times  and  
set  the  temperature  at  120°F  (49°C).
●   
  Press  and  hold  the  UP  button  on  remote  control  
for  more  than  5  seconds.  Number  (120)  on  the  
display  of  the  remote  control  will  begin  to  blink.  
●   
  While  the  number  is  blinking,  push  the  UP  arrow  
temperature  adjustment  button  and  the  Down  
arrow  temperature  adjustment  button  at  the  same  
time.  The  display  of  the  remote  control  will  show  
“140”.    
●   
Push  the  UP  or  Down  button  to  set  desired  
temperature.  
●   
Turn  on  the  gas  and  water  shut  off  valves.
●   
Check  and  ensure  safe  operation  and  performance  
of  the  water  heater.
See  steps  below  to  LIMIT  maximum  water  
temperature  setting  to  120°F  (49°C).
●   
Turn  on  the  remote  control.  Turn  off  the  gas  and  
water  shutoff  valves.
●   
Press  the  Down  arrow  temperature  adjustment  
button  on  the  remote  control  for  several  times  and  
set  the  minimum  setting  temperature  (100°F(38°C)  
or  85°F(29°C)).
●   
Press  and  hold  the  Down  button  on  the  remote  
control  for  more  than  5  seconds.  Number  on  the  
display  of  the  remote  control  will  begin  to  blink.
●   
While  the  number  is  blinking,  push  the  Down  arrow  
temperature  adjustment  button  and  the  UP  arrow  
temperature  adjustment  button  at  the  same  time.    
Number  of  the  display  of  the  remote  control  will  stop  
blinking.
●   
Push  the  UP  or  Down  button  to  set  desired  
temperature.
●   
Turn  on  the  gas  and  water  shut  off  valves.
●   
Check  and  ensure  safe  operation  and  performance  
of  the  water  heater.  
Maximum  Temperature  Adjustment  by  the  Main  
Remote  Control  (UMC-­117)
The  content  on  this  page  is  intended  for  use  by  qualified    
installation/service  personnel  ONLY.
WARNING:  Improper  adjustment,  alteration,  
service  or  maintenance  can  cause  property  damage,  
personal  injury,  or  death.
Time/Temperature  Relationship  in  Scalds
  
!
DANGER:  Hotter  water  increases  
the  potential  for  Hot  Water  SCALDS.
120°F  (49°C)
More  than  5  minutes
125°F  (52°C)
1-­1/2  to  2  minutes
130°F  (54°C)
About  30  seconds
135°F  (57°C)
About  10  seconds
140°F  (60°C)
Less  than  5  seconds
145°F  (63°C)
Less  than  3  seconds
150°F  (66°C)
About  1-­1/2  seconds
155°F  (68°C)
About  1  second
Table  courtesy  of  Shriners  Burn  Institute
      Water  Temperature              
Time  To  Produce  a  Serious  Burn
34
°F
PRIORITY 
POWER 
ON/OFF
Higher  (Hotter)  
Lower  (Cooler)  
    100  102  104  106  108  110  112  114  116  118  120*
      38      39      40      41      42      43      44      46      47      48      49*
85
29
125  130  140  
°F
52      54      60  
°C
In  Use  Indicator  
(Lit  during  operation)
LED  Display  
(Displays  water  temperature  and  error  codes)
ON/OFF  
Indicator
Temperature  
Adjustment  
Buttons
Priority  Indicator
Notice:  Display  shows  °F  only.
AP15317 (10_09)  DV Gas Manual 10 30 09.indd   34