VA Series Outdoor LS Manual 
  Setting the Sound Volume
  
(Voice Prompt)
   
 
 
 
 
 
 
 
 
 
BC-100V 
Press the “Sound Vol.” button to 
adjust the voice prompt volume.   
The default sound volume is set 
to Medium.  Each subsequent 
press of the button cycles 
through the volume levels in the 
order below. 
  Setting the Clock
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MC-100V  Press the “Function” button to 
adjust the voice prompt 
volume.  The default sound 
volume is set to Medium.  
Each subsequent press of the 
 or 
 button cycles through 
the volume levels in the order 
below. 
MC-100V  Press the “Function” button twice within 10 seconds to set the clock.  Press the 
 or 
 button to reach the desired time.  The clock on the BC-100V automatically shows 
the time which has been set on the MC-100V.   
  Temperature Ranges
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This water heater will attempt to provide hot water at the temperature even when the water flow is varied or when 
more than 1 tap is in use.  The water heater can deliver water at only one temperature setting at a time.  The 
available temperatures for a given model are provided below. 
Suggested temperatures are 
Kitchen 
120 ºF (49º C) 
Shower 
98º - 110º F (37º - 43º C) 
Bath Fill  102º - 110º F (39º - 43º C) 
These temperatures are suggestions only. 
Temperature lower than 98º F (37º C) can be obtained 
at the tap by mixing with cold water. 
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 
5 seconds while the water heater is OFF. 
*  These settings require the MCC-91 controller.  When the MCC-91 controller is connected, these higher 
temperature 
If a space heating application requires higher than 140º F then a mixing valve shall be installed to temper the 
water temperature to 140º F or less for domestic use.
are available on all controller models in the system. 
Model 
Temperature Settings Available (ºF) 
R63LSe 
98  100 102 104 106 108 110 115 120 125 130 135 140 150 160 
R75LSe 
98  100 102 104 106 108 110 115 120 125 130 135 140 150 160 
R94LSe 
R98LSe 
R98LSe-ASME 
98  100 102 104 106 108 110 115 120 125 130 135 140 150 160 185 
Temp in Celsius  ºC 
37 
38 
39 
40 
41 
42 
43 
46 
49 
52 
54 
57 
60 
66 
71 
85 
 
Medium Volume 
(default) 
High Volume 
Off Volume  
(beep) 
Off Sound  
(no beep) 
Low Volume