Rinnai R63LSE2 用户手册

下载
页码 40
 
 
VA Series Outdoor LS Manual 
Specifications 
Model 
R63LSe2 
R75LSe  
R94LSe  
R98LSe  
R98LSe-
ASME 
Minimum Gas Consumption Btu/h  
 
15,000
19,000
Maximum Gas Consumption Btu/h  
150,000 
199,000 
180,000 237,000 
Hot water capacity (Min - Max) * 
0.6 - 6.3 GPM 
(2.3 - 24 L/min) 
0.6 - 7.5 GPM 
(2.3 - 28 L/min) 
 L/min) 
0.6 - 9.4 GPM 
(2.3 - 35.5
0.6 - 9.8 GPM 
(2.3 - 37 L/min) 
Hot water capacity, (45ºF rise)  
5.5 GPM 
(20.8 L/min)
6.6 GPM 
(25 L/min)  
7.4 GPM 
(28 L/min)  
8.7 GPM 
(33 L/min) 
Default Temperature Setting (no controller)  
120º F (49º C) 
Temperature Controller Default Setting 
104º F (40º C) 
Maximum Temp Setting (Commercial **) 
160º F (71º C)    
                                                      
185º F (85º C)  
Maximum Temp Setting (Residential) 
Selectable at 120º F (49º C) or at 140º F (60º C) 
140º F (60º C) 
Minimum Temperature Setting  
98º F (37º C) 
Weight  
46 lb 
(21 kg) 
55 lb 
(25 kg) 
Efficiency Rating  
 
 
Noise level  
49 dB (A) 
Electrical 
Consumption  
Normal  
45 W 
50 W 
55 W 
72 W 
Standby  
Anti-frost Protection  
100 W 
116 W 
By-Pass Control  
Fixed 
Electronic 
Minimum Gas Supply 
Pr
see Temperature Ranges for more information
essure  
Natural Gas  
5.0 inch W.C. 
Propane  
8.0 inch W.C. 
Maximum Gas Supply 
Pressure  
Natural Gas  
10.5 inch W.C. 
Propane  
13.5 inch W.C. 
Type of Appliance  
Temperature controlled continuous flow gas hot water system.  
Operation  
With or without temperature controls, mounted in kitchen, bathroom, etc.  
Approved Gas Type  
Natural Gas or Propane - Ensure unit matches gas type it's being installed on.  
Connections  
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT  
Ignition System  
Direct Electronic Ignition  
Electric Connections  
Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)  
Water Temperature Control  
Simulation Feedforward and Feedback.  
Water Supply Pressure  
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)  
Maximum Water Supply Pressure  
150 PSI  
Temperature Control Cable  
Non-Polarized Two Core Cable (Minimum 22 AWG) 
2 W  
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prio
** for commercial and hydronic applications requiring higher temperatures.
r notice. 
The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value 
listed is for the purpose of input adjustment. 
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. 
83.0% 
Energy Star Qualified 
No 
Yes
Yes Yes 
No