VA Series Indoor LS Manual 
15 
  Trouble Shooting for Common Issues 
 
 
 
                 
I don’t have any hot water when I open the tap. 
Make sure there is gas, water, and electricity to the 
Rinnai water heater (power is turned on and the gas is 
turned on). 
When I was using the hot water, the water got cold. 
If you adjusted the flow from the tap to lessen it, you  
may have gone below the minimum flow required.  The 
Rinnai water heater requires a minimum flow rate to 
operate.  (See the specification page for the flow rate 
of your model.)  Decrease the temperature setting at 
the temperature controller or increase the water flow. 
White smoke comes out of the exhaust. 
During colder weather when the exhaust temperature 
is much hotter than the outside air, the exhaust fumes 
condense producing water vapor. 
When I open a hot tap, I do not immediately get hot 
water. 
Hot water must travel through your plumbing from the 
Rinnai water heater to the faucet.  The time period for 
hot water to reach your fixture is determined by the 
amount of water in the plumbing system between the 
water heater and the fixture, water pressure, and the 
flow rate of the fixture. 
After I turn off the hot water tap, the fan on the 
Rinnai water heater continues to run. 
The fan is designed to continue running for a short time 
after the flow of water stops.  This is to ensure constant 
water temperatures during rapid starting and stopping, 
as well as exhausting any residual gas flue products 
from the unit. 
Consideration of care for your water heater should  
include evaluation of water quality.  If the water quality 
exceeds the target levels provided in the table, you 
may want to treat or condition the water. 
* Source: Part 143 National Secondary Drinking Water 
Regulations 
 
Maximum Level 
Total Hardness 
Up to 200 mg / L 
Aluminum * 
Up to 0.2 mg / L 
Chlorides * 
Up to 250 mg / L 
Copper * 
Up to 1.0 mg / L 
Iron * 
Up to 0.3 mg / L 
Manganese * 
Up to 0.05 mg / L 
pH * 
6.5 to 8.5 
TDS (Total Dissolved 
Solids) * 
Up to 500 mg / L 
Zinc * 
Up to 5 mg / L 
  Water Quality   
 
 
 
 
 
 
 
 
 
                 
  Accessing 
Operating 
Information 
        
         
To display the most recent error codes press and hold the “On/Off” button for 2 seconds.  While holding the “On/
Off” button press the ▲ button.  The last 9 error codes will flash one after the other.  To exit this mode press the 
“On/Off” and ▲ button as before. 
To display the water flow through the water heater press and hold the ▲ button for 2 seconds and without 
releasing the ▲ button press the “On/Off” button.  
To display the outlet water temperature press and hold the ▼ button for 2 seconds and without releasing the ▼ 
button press the “On/Off” button.   
Models MC-91 and MCC-91