Manual - Rinnai Condensing Water Heaters 
  Temperature Controller Installation   
 
 
 
 
 
 
 
 
 
 
 
1.  Determine a suitable location for the 
controller. 
2.  Make three holes in the wall as shown. 
3.  Run the cable between the controller and the 
Rinnai water heater or the controller and the 
other controller. 
4.  Remove the face plate from the temperature 
controller using a screwdriver. 
5.  Connect the cable to the temperature 
controller. 
6.  Mount the controller to the wall using the 
holes drilled in step 2. 
7.  Disconnect the power from the Rinnai water 
heater. 
8.  Remove the cover of the Rinnai water heater. 
9.  Remove the plastic cover from the PC board 
and electrical connections. 
10. Thread the cable through the access hole at 
the base of the unit and connect the wires to 
the controller terminals on the right hand side 
bottom of the PC board. 
11. Secure the controller cable using the clamp 
provided. 
12. Replace plastic cover over PC board and then 
replace the cover of the Rinnai water heater. 
Do not attempt to connect the temperature controllers 
with the power on.  There is 120 volt potential, next to 
the temperature controller connections inside the unit.   
Do not connect the temperature controller to the 
120VAC terminals provided for the optional 
solenoid drain valves.   
All service and wiring should be performed by a 
registered installer. 
     WARNING 
Outline of Remote
securing screw
1-21/32"
3-5/16"
securing screw
wiring hole
Mounting the Controller 
Follow the procedure below to install MC-91 or 
MCC-91 temperature controllers.