Rinnai R98LSE-ASME 用户手册

下载
页码 40
 
VA Series Outdoor LS Manual 
29 
  High 
Altitude 
Installations 
    
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
ON
F
F
O
Switch No.
1
2
3
4
5
6
7
8
ON
F
F
O
Switch No.
1
2
3
4
5
6
7
8
ON
F
F
O
Switch No.
1
2
3
4
5
6
7
8
ON
F
F
O
Switch No.
 
0-2000 ft 
(0-610 m) 
2001-5200 ft 
(610-1585 m) 
5201-7700 ft 
(1585-2347 m) 
7701-10200 ft 
(2347-3109 m) 
Switch No. 2 
OFF 
OFF 
ON 
ON 
Switch No. 3 
OFF 
ON 
OFF 
ON 
 
 
 
 
 
 
 
 
 
 
 
 
Set dip switches 2 and 3 to the values shown in table 
below for your altitude.  The default setting for the 
appliance is 0-2000 ft (0-610 m) with switches No. 2 
and No 3 in the OFF position. 
  Connecting Multiple Water Heaters   
 
 
 
 
 
 
 
 
 
 
 
 
The EZConnect™ cable is an optional accessory that 
connects 2 water heaters and allows them to function 
as one hot water source.  (The EZConnect™ cannot 
be used on the R63LSe.)
The MSA packs are optional accessories that connect 
2 to 5 water heaters and allow them to function as one 
hot water source. 
Refer to the instructions that come with the accessory 
for complete installation information. 
Number of 
Connected 
Water 
Heaters: 
(R98LSe, R98LSe-ASME, R94LSe, 
R75LSe)
Accessories Necessary: 
(1) EZConnect™ Cable 
or
 
(1) MSA-2M 
(1) MSA-2M 
and
 (1) MSA-2S 
(1) MSA-2M 
and 
(2) MSA-2S 
(1) MSA-2M 
and 
(3) MSA-2S 
R63LSe
R98LSe, R98LSe-ASME, R94LSe, R75LSe
 
to manifold 2 to 5 Rinnai water heaters in order to 
produce a stable water temperature and allow the 
water heaters to run efficiently.  Water heaters will turn 
on as necessary to meet the demand for hot water.
the same temperature setting.
When using PVA valves, water heaters should be at 
used on this model.
The EZConnect™, MSA-2MB, and MSA-2S cannot be 
for complete installation information.
Refer to the instructions that come with the accessory 
     WARNING 
DO NOT adjust the other dip 
switches unless specifically 
instructed to do so. 
Rinnai pressure activation valves (PVA’s) can be used 
Guidelines 
Do not install both the EZConnect™ and the MSA 
packs because they are not designed to operate 
together. 
Water heaters connected with the EZConnect™ 
Cable or the MSA packs cannot be used for the 
Bath Fill function. 
Water heaters should be installed less than 18 
inches apart so that the cables will reach between 
units and to prevent temperature fluctuations (cold 
water sandwich effect) when the water is shut off 
and turned back on. 
When using EZConnect™ Cable or the MSA packs, 
temperature settings can only be changed on the 
controller for the primary unit.