VB Series Indoor LS Manual 
Specifications 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prior notice. 
The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value 
listed is for the purpose of input adjustment. 
Model 
RL75i 
RL94i 
R98LSi 
R98LSi-ASME 
Minimum Gas Consumption Btu/h  
9,900 (NG) 
10,300 (LPG) 
19,000 
Maximum Gas Consumption Btu/h  
180,000 
199,000 (NG) 
190,000 (LP) 
237,000 
Hot water capacity (Min - Max) * 
0.4 - 7.5 GPM 
(1.5 - 28.5 L/min) 
0.4 - 9.4 GPM 
(1.5 - 35.5 L/min) 
0.6 - 9.8 GPM 
(2.4 - 37 L/min) 
Hot water capacity (45°F rise)  
6.6 GPM 
(25.0 L/min)  
7.1 GPM 
(27.0 L/min)  
8.5 GPM 
(32.2 L/min) 
Default Temperature Setting (no controller)  
120º F (49º C)  
 
Temperature Controller Default Setting 
104º F (40º C) 
 
Maximum Temp Setting (commercial **) 
160º F (71º C)   
185º F (85º C)   
Maximum Temp Setting (residential)  
see Temperature Ranges for more information 
Selectable at 120º F (49º C) or at 140º F 
(60º C)  
140º F (60º C)  
Minimum Temperature Setting  
98º F (37º C) 
Weight  
51 lb (23 kg) 
53 lb (24 kg) 
55 lb (25 kg) 
Efficiency 
Thermal Efficiency:  84.0%  
 
Noise level  
49 dB  
Electrical Consumption  
Normal  
76 W 
83 W 
99 W 
Standby  
2 W 
Anti-frost Protection  
184 W 
 
116 W 
By-Pass Control  
Fixed 
Electronic 
Minimum Gas Supply 
Pressure  
Natural Gas  
5.0 inch W.C. 
Propane  
8.0 inch W.C. 
Maximum Gas Supply 
Pressure  
Natural Gas  
10.5 inch W.C. 
Propane  
13.5 inch W.C. 
Type of Appliance  
Direct Vent, Temperature controlled continuous flow gas hot water system.  
Operation  
With or without remote controls, mounted in kitchen, bathroom, etc.  
Approved Gas Type  
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation 
Connections  
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT  
Ignition System  
Direct Electronic Ignition  
Electric Connections  
Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)  
Water Temperature Control  
Simulation Feedforward and Feedback.  
Water Supply Pressure  
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum 
Maximum Water Supply Pressure  
150 PSI  
Remote Control Cable  
Non-Polarized Two Core Cable (Minimum 22 AWG) 
Energy Star Qualified 
Yes 
Yes 
No (not applicable) 
Certified for installation in manufactured (mobile) 
homes 
Yes 
Yes 
No 
No 
Energy Factor:  0.82 
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. 
** for commercial and hydronic applications requiring higher temperatures